1 - 27
1 Overview
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
1-
5 Com
p
ar
is
on
wit
h
Previou
s
Model
1
The following monitor functions are added or improved to enhance the recognition of operations in your
application.
The default data of the following parameters are changed from the conventional 3G3MX2 Series.
Check if these default values are appropriate for your application.
Additions/Changes of Monitor Function
Parameter
No.
Parameter name
Previous model
d008
Real Frequency Monitor
Improved to be displayed always when the Pulse Train Input RP
Selection (P003) is set to 01 (Feedback pulse).
d023
Program Counter
(DriveProgramming)
Added as monitor functions for the DriveProgramming function.
d024
Program Number Monitor
(DriveProgramming)
d025
User Monitor 0
(DriveProgramming)
d026
User Monitor 1
(DriveProgramming)
d027
User Monitor 2
(DriveProgramming)
d030
Current Position Monitor
Improved to be displayed always when the Pulse Train Input RP
Selection (P003) is set to 01 (Feedback pulse).
d062
Frequency Reference Source
Monitor
Added to monitor the enabled frequency reference.
d063
RUN Command Source Monitor
Added to monitor the enabled RUN command.
d130
Analog Voltage Input FV Monitor
Added to monitor the analog voltage input terminal FV.
d131
Analog Current Input FI Monitor
Added to monitor the analog current input terminal FI.
d133
Pulse Train Input RP Monitor
Added to monitor the pulse train input terminal RP.
d153
PID Deviation
Added to monitor the deviation in PID control.
d155
PID Output Monitor
Added to monitor the PID control operation output.
Changes of Default Parameter Setting
Parameter
No.
Parameter name
Default data
Description
Previous
model
3G3MX2-V1
A041
1st Torque Boost Selection
00
01
Changed to enable the automatic
torque boost function.
A241
2nd Torque Boost Selection
00
01
A047
1st Automatic Torque Boost
Slip Compensation Gain
100
0
Changed to disable the automatic
torque boost slip compensation
function.
A247
2nd Automatic Torque
Boost Slip Compensation
Gain
100
0
b027
Overcurrent Suppression
Selection
00
01
Changed to enable the overcurrent
suppression function.
b037
Display Selection
04
00
Changed to display all parameters.
b082
Starting Frequency
0.50
1.50
Changed to 1.5 Hz.
b130
Overvoltage Suppression
Function Selection During
Deceleration
00
01
Changed to enable the overvolt-
age suppression function
C102
Reset Selection
00
02
Changed to enable only when an
error occurs.
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...