11 Maintenance and Inspection
11 - 2
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
11-1 Maintenance and Inspection
• Be sure to confirm safety before conducting maintenance, inspection or parts replacement.
• The capacitor service life is influenced by the ambient temperature. Refer to “Smoothing Capacitor
Life Curve” described in the manual. When a capacitor reaches the end of its service life and does
not work as the product, you need to replace the capacitor.
• Provide a separate emergency stop switch because the STOP Key on the Operator is valid only
when function settings are performed.
• When checking a signal during the power supply and the voltage is erroneously applied to the control
input terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal.
• Inverters contain components and will operate properly only when each component operates normally.
Some of the electrical components require maintenance depending on application conditions. Periodic
inspection and replacement are necessary to ensure proper long-term operation of inverters. (Quoted
from The Recommendation for Periodic Maintenance of a General-purpose Inverter published by JEMA.)
• When a cooling fan reaches the end of its service life, replace it.
WARNING
Do not change wiring and slide switches, put on or take off Operator and optional devices, replace
cooling fans while the input power is being supplied.
Doing so may result in a serious injury due to an electric shock.
Do not remove the terminal cover during the power supply and 10 minutes after the power shut off.
Doing so may result in a serious injury due to an electric shock.
Do not touch the inverter cooling fins, braking resistors, and the motor, which become too hot dur-
ing the power supply and for some time after the power shut off. Doing so may result in a burn.
CAUTION
Do not dismantle, repair or modify the product.
Doing so may result in an injury.
Precautions for Safe Use
Maintenance and Inspection
Precautions for Correct Use
Operation Stop Command
Maintenance and Parts Replacement
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...