![background image](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918294.webp)
6 Vector Control and Applied Functions
6 - 52
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
b122
Acceleration Wait Time
on Brake Control
0.00 to 5.00
Set the mechanical delay time from when the
brake confirmation signal (or brake release
signal) turns ON until the brake is activated
actually.
0.00
s
b123
Stop Wait Time on
Brake Control
0.00 to 5.00
Set the mechanical delay time from when the
brake release signal turns OFF until the brake
is forced actually.
The creep operation time or the stop wait
time, whichever is longer, takes priority. Set a
sufficient time that causes the brake to be
activated and applied without fail.
0.00
s
b124
Brake Error Detection
Time
0.00 to 5.00
Set this to equal to or longer than the time
until the brake confirmation signal turns ON
after the brake release signal is output.
0.00
s
b126
Brake Release Current
*3
0.00 to 2.00
×
Rated current of inverter
Set an output current value sufficient enough
to support the load and output the brake
release signal.
Rated
current of
inverter
A
C001 to C007
Multi-function Input S1
to S7 Selection
44:
BOK (Brake confirmation)
−
−
C021, C022
Multi-function Output
P1/P2 Selection
−
−
19:
BRK (Brake release)
20:
BER (Brake error)
C026
Multi-function Relay
Output (MA, MB) Func-
tion Selection
23:
POK (Positioning ready)
05
−
*1. If the creep speed setting is too low, the inverter may not be able to output a sufficient torque to keep the load
in position. Set such a frequency that enables the inverter to stably output a sufficient torque.
*2. DC injection braking is enabled when the interlock function with simple position control and brake control is
used. DC injection braking works even when the inverter is stopped to support its load holding capability. This
is effective, for example, to prevent fall accidents when the brake is forced.
*3. If the set value is too low, the inverter may not output a sufficient torque when the brake is released.
Parameter
No.
Function name
Data
Default
data
Unit
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...