10 - 5
10 Troubleshooting
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
10-
1 Alarm
Displ
ay and
Rem
e-
di
es
10
1
0-1-2
Alar
m Code List
Name
Description
Alarm
code
Check and remedy
Reference
page
Overvoltage
protection
Extremely high DC voltage between
P/
+
2 and N/
−
may result in a fault.
Therefore, the inverter trips if the DC
voltage between P/
+
2 and N/
−
exceeds approximately 400 VDC (for
200-V class) or 800 VDC (for 400-V
class) due to regenerative energy
from the motor or an increase in the
incoming voltage.
E07.
Is there any rapid deceleration?
• Increase the deceleration time.
Is there any ground fault?
• Check the output wiring and
the motor.
Is the motor rotated from the load
side?
• Decrease the amount of
regeneration.
Is the incoming voltage too high?
• Lower the incoming voltage,
suppress the power supply
fluctuation, install the AC reac-
tor in the input power circuit.
P. 2-31
P. 5-33
P. 5-63
P. 5-65
P. 7-42
EEPROM
error
*1
*1. If this error occurs, the inverter will not accept the reset operation via the terminal RS or the STOP/RESET key.
Turn off the power supply once.
If this error is still displayed at the next power-on, it is possible that the memory is corrupt or the parameters
are not stored correctly. Perform parameter initialization to reset the parameter settings.
The inverter trips if an error occurs in
the built-in EEPROM due to external
noise or abnormal temperature rise.
(This may result in a CPU error.)
E08.
Is there any large noise source
around?
• Take measures against noise.
Is the cooling efficiency reduced?
• Check the cooling fin for
clogging and clean it.
• Replace the cooling fan.
−
Undervoltage
The inverter shuts off its output if the
incoming voltage drops below the
specified level, because the control
circuit fails to work properly at such a
low incoming voltage. Then, the
inverter trips if the DC voltage
between P/
+
2 and N/
−
exceeds drops
to approximately 173 VDC (for 200-V
class) or 345 VDC (for 400-V class) or
lower.
E09.
Is the power supply voltage
decreased?
• Check the power supply.
Is the power supply capacity suffi-
cient?
• Check the power supply.
Is the thyristor in the inrush cur-
rent protection circuit broken?
• Check that the DC voltage
between P/
+
2 and N/
−
decreases only at large out-
put current values.
P. 7-68
Current
detector error
The inverter trips if an error occurs in
the current detector.
E10.
The inverter has a defect.
• Repair it.
−
CPU error
*1
The inverter trips if a malfunction or
error occurs in the built-in CPU.
E11.
Is there any large noise source
around?
• Take measures against noise.
The inverter has a defect.
• Repair it.
−
External trip
The inverter trips if the multi-function
input terminal allocated to the Exter-
nal trip (12: EXT) function turns ON.
E12.
The external equipment has a
defect.
• Check the external equipment.
P. 7-79
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...