![Omron SYSDRIVE MX2 SERIES User Manual Download Page 528](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918528.webp)
10 Troubleshooting
10 - 12
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
If the set parameter contradicts other set value, the inverter will display a warning with the program LED
blinking.
The table below lists the warning displays and their display conditions. If the warning display appears,
change the parameter setting according to this table. (Inputting the RUN command does not rewrite the
correct parameter value automatically.)
The latest warning display is stored in the parameter d090.
10-1-4 Warning Display
Warning display
Warning display conditions
1st Frequency Upper Limit (A061)
>
1st Maximum Frequency (A004)
1st Frequency Lower Limit (A062)
>
1st Maximum Frequency (A004)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
>
1st Maximum Frequency (A004)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
>
1st Frequency Upper Limit (A061)
1st Frequency Lower Limit (A062)
>
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
Starting Frequency (b082)
>
1st Frequency Upper Limit (A061)
Starting Frequency (b082)
>
1st Frequency Lower Limit (A062)
Starting Frequency (b082)
>
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
Starting Frequency (b082)
>
Jogging Frequency (A038)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
=
Jump Frequency
*1
(A063/A065/A067 ± A064/A066/A068)
*1. A warning will occur if the frequency set in F001, A020, A220, or A021 to A035 is within the frequency range
set in the frequency jump function.
Multi-step Speed Reference 1 to 15
(A021 to A035)
=
Free V/f Frequency 7 (b112)
>
1st Frequency Upper Limit (A061)
Free V/f Frequency 7 (b112)
>
1st Frequency Lower Limit (A062)
Free V/f Frequency 7 (b112)
>
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
2nd Frequency Upper Limit (A261)
>
2nd Maximum Frequency (A204)
2nd Frequency Lower Limit (A262)
>
2nd Maximum Frequency (A204)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
>
2nd Maximum Frequency (A204)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
>
2nd Frequency Upper Limit (A261)
2nd Frequency Lower Limit (A262)
>
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Starting Frequency (b082)
>
2nd Frequency Upper Limit (A261)
Starting Frequency (b082)
>
2nd Frequency Lower Limit (A262)
Starting Frequency (b082)
>
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
=
Jump Frequency
*1
(A063/A065/A067 ± A064/A066/A068)
Free V/f Frequency 7 (b112)
>
2nd Frequency Upper Limit (A261)
Free V/f Frequency 7 (b112)
>
2nd Frequency Lower Limit (A262)
Free V/f Frequency 7 (b112)
>
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...