![Omron SYSDRIVE MX2 SERIES User Manual Download Page 162](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918162.webp)
4 Parameter List
4 - 28
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Le
vel
and
o
utput termin
al
st
atus
C042
Arrival Frequency
During Acceleration
1
0.00:
Not output arrival signal
during acceleration.
0.00
Disabled
Enabled
Hz
P. 7-81
0.01 to 99.99
100.0 to 400.0
*1
C043
Arrival Frequency
During
Deceleration 1
0.00:
Not output arrival signal
during deceleration.
0.00
Disabled
Enabled
Hz
0.01 to 99.99
100.0 to 400.0
*1
C044
PID Deviation
Excessive Level
0.0 to 100.0
3.0
Disabled
Enabled
%
P. 7-44
C045
Arrival Frequency
During Acceleration
2
0.00:
Not output arrival signal dur-
ing acceleration.
0.00
Disabled
Enabled
Hz
P. 7-81
0.01 to 99.99
100.0 to 400.0
*1
C046
Arrival Frequency
During
Deceleration 2
0.00:
Not output arrival signal dur-
ing deceleration.
0.00
Disabled
Enabled
Hz
0.01 to 99.99
100.0 to 400.0
*1
C047
Pulse Train Output
MP Scale
0.01 to 99.99
1.00
Enabled
Enabled
−
P. 7-28
C052
Feedback Compar-
ison Signal Off
Level
0.0 to 100.0
100.0
Disabled
Enabled
%
P. 7-44
C053
Feedback Compar-
ison Signal On
Level
0.0 to 100.0
0.0
Disabled
Enabled
%
C054
Overtorque/Under-
torque Selection
00: Overtorque
00
Disabled
Enabled
−
P. 6-15
01: Undertorque
C055
Overtorque/Under-
torque Level
(Forward Power
Running)
0. to 200.
100.
Disabled
Enabled
%
C056
Overtorque/Under-
torque Level
(Reverse Regener-
ation)
100.
Disabled
Enabled
C057
Overtorque/Under-
torque Level
(Reverse Power
Running)
100.
Disabled
Enabled
C058
Overtorque/Under-
torque Level
(Forward Regener-
ation)
100.
Disabled
Enabled
C059
Overtorque/Under-
torque Signal Oper-
ation
00: Enabled during acceleration/
deceleration and constant
speed
01
Disabled
Enabled
−
01: Enabled only during constant
speed
C061
Electronic Thermal
Warning Level
0. to 100.
90.
Disabled
Enabled
%
P. 7-75
C063
0 Hz Detection
Level
0.00 to 99.99
100.0
0.00
Disabled
Enabled
Hz
P. 5-58
C064
Cooling Fin Over-
heat Warning Level
0. to 110.
100.
Disabled
Enabled
°C
P. 7-86
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...