![Omron SYSDRIVE MX2 SERIES User Manual Download Page 470](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918470.webp)
8 Communications Functions
8 - 58
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1274 hex
1273 hex
1st Acceleration
Time 2
A092
(HIGH)
R/W
0 to 360000
0.01 [s]
P. 5-37
1275 hex
1274 hex
A092
(LOW)
R/W
1276 hex
1275 hex
1st Deceleration
Time 2
A093
(HIGH)
R/W
0 to 360000
0.01 [s]
1277 hex
1276 hex
A093
(LOW)
R/W
1278 hex
1277 hex
1st 2-step
Acceleration/
Deceleration
Selection
A094
R/W
00:
Switch via 2CH
terminal
(multi-function
input: 09)
−
01:
Switch by setting
(A095/A295/A096/
A296)
02:
Switch only during
forward/reverse
switching
1279 hex
1278 hex
1st 2-step
Acceleration
Frequency
A095
(HIGH)
R/W
0 to 40000
*1
0.01
[Hz]
127A hex
1279 hex
A095
(LOW)
R/W
127B hex
127A hex
1st 2-step
Deceleration
Frequency
A096
(HIGH)
R/W
0 to 40000
*1
0.01
[Hz]
127C hex
127B hex
A096
(LOW)
R/W
127D hex
127C hex
Acceleration Pattern
Selection
A097
R/W
00:
Line
−
P. 5-34
01:
S-shape curve
02:
U-shape curve
03:
Inverted U-shape curve
04:
EL-S-shape curve
127E hex
127D hex
Deceleration Pattern
Selection
A098
R/W
00:
Line
−
01:
S-shape curve
02:
U-shape curve
03:
Inverted U-shape
curve
04:
EL-S-shape curve
127F hex
−
Reserved
−
−
−
−
−
1280 hex
1281 hex
1280 hex
FI Start Frequency
A101
(HIGH)
R/W
0 to 40000
*1
0.01
[Hz]
*2
P. 7-25
1282 hex
1281 hex
A101
(LOW)
R/W
1283 hex
1282 hex
FI End Frequency
A102
(HIGH)
R/W
0 to 40000
*1
0.01
[Hz]
*2
1284 hex
1283 hex
A102
(LOW)
R/W
1285 hex
1284 hex
FI Start Ratio
A103
R/W 0 to 100
1 [%]
1286 hex
1285 hex
FI End Ratio
A104
R/W 0 to 100
1 [%]
1287 hex
1286 hex
FI Start Selection
A105
R/W
00:
FI Start Frequency
(A101)
−
01:
0 Hz
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
*2. When the PID function is enabled, the data unit differs between read and write operations.
Set parameter values in units of 0.01 Hz for writing and in units of 0.1% (as 100% of the maximum frequency)
for reading.
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...