12 Options
12 - 46
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
12-14CompoNet Communications Unit
(Model: 3G3AX-MX2-CRT-E)
12-14-1 Specifications
Item
Specifications
Mounting
Unit type
MX2 Series CompoNet Communications Unit
Model
3G3AX-MX2-CRT-E
Weight
100 g max. (Shipping weight: Approx. 170 g)
Environment
Operating ambient
temperature
−
10 to 50°C (with no freezing or condensation)
Operating ambient humidity 20% to 90%
Storage ambient temperature
−
20 to 65°C (with no freezing or condensation)
Vibration resistance
5.9 m/s
2
(0.6 G), 10 to 55 Hz
Dielectric strength
500 VAC (between isolated circuits)
Location
At a maximum altitude of 1,000 m, indoors (without corrosive
gases or dust)
Compliance with EMC and
electrical safety standards
EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EN61800-5-1: 2007(2006/95/EC) SELV
UL/cUL standard
UL508
Internal power supply
Supplied from inverter
Enclosure rating
IP20
CompoNet
interface
Communications protocol
CompoNet
Certification
CompoNet conformance test
CompoNet profile
AC drive (0
×
02)
Supported connections
Remote I/O: Master-Slave connection
Poll
Explicit message
Conforming to the CompoNet specifications
Communications power
supply
−
(External power supply not required)
Unit device address range Node address MAC ID 0 to 63, set via inverter parameter P190 or
rotary switch
Supported baud rates
4 Mbps, 3 M bps, 1.5 Mbps, or 93.75 kbps
Automatic baud rate detection by Master Unit
CompoNet
configuration
Default connection path
Supported, set via inverter parameter P046
Supported assemblies
Basic Speed I/O (Output assembly 20, Input assembly 70)
Extended Speed I/O (21, 71)
Extended Speed and Torque Control (123, 173)
Special I/O (100, 150)
Extended Control I/O (101, 151)
Extended Control I/O and Multi-function Input Monitor (101, 153)
Flexible format (139, 159)
Extended Speed and Acceleration Control (110, 111)
*1
*1. Use the specified output and input assembly pair.
EDS file
Dependent on inverter model
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...