![background image](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918500.webp)
8 Communications Functions
8 - 88
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
165D hex
165C hex
Position Store
Selection at Power
Off
P081
R/W
00:
Not store
−
P. 6-44
01:
Store
165E hex
165D hex
Position Data at
Power Off
P082
(HIGH)
R/W
Position range setting
(reverse side) to posi-
tion range setting (for-
ward side)
1
[pulse]
165F hex
165E hex
P082
(LOW)
1660 hex
165F hex
Preset Position Data
P083
(HIGH)
R/W
Position range setting
(reverse side) to posi-
tion range setting (for-
ward side)
1
[pulse]
P. 6-43
1661 hex
1660 hex
P083
(LOW)
1662 to
1665 hex
−
Reserved
−
−
−
−
−
1666 hex
1665 hex
DriveProgramming
User Parameter U00
P100
R/W 0 to 65535
1
P. 7-102
1667 hex
1666 hex
DriveProgramming
User Parameter U01
P101
R/W 0 to 65535
1
1668 hex
1667 hex
DriveProgramming
User Parameter U02
P102
R/W 0 to 65535
1
1669 hex
1668 hex
DriveProgramming
User Parameter U03
P103
R/W 0 to 65535
1
166A hex
1669 hex
DriveProgramming
User Parameter U04
P104
R/W 0 to 65535
1
166B hex
166A hex
DriveProgramming
User Parameter U05
P105
R/W 0 to 65535
1
166C hex
166B hex
DriveProgramming
User Parameter U06
P106
R/W 0 to 65535
1
166D hex
166C hex
DriveProgramming
User Parameter U07
P107
R/W 0 to 65535
1
166E hex
166D hex
DriveProgramming
User Parameter U08
P108
R/W 0 to 65535
1
166F hex
166E hex
DriveProgramming
User Parameter U09
P109
R/W 0 to 65535
1
1670 hex
166F hex
DriveProgramming
User Parameter U10
P110
R/W 0 to 65535
1
1671 hex
1670 hex
DriveProgramming
User Parameter U11
P111
R/W 0 to 65535
1
1672 hex
1671 hex
DriveProgramming
User Parameter U12
P112
R/W 0 to 65535
1
1673 hex
1672 hex
DriveProgramming
User Parameter U13
P113
R/W 0 to 65535
1
1674 hex
1673 hex
DriveProgramming
User Parameter U14
P114
R/W 0 to 65535
1
1675 hex
1674 hex
DriveProgramming
User Parameter U15
P115
R/W 0 to 65535
1
1676 hex
1675 hex
DriveProgramming
User Parameter U16
P116
R/W 0 to 65535
1
1677 hex
1676 hex
DriveProgramming
User Parameter U17
P117
R/W 0 to 65535
1
1678 hex
1677 hex
DriveProgramming
User Parameter U18
P118
R/W 0 to 65535
1
1679 hex
1678 hex
DriveProgramming
User Parameter U19
P119
R/W 0 to 65535
1
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...