4 - 25
4 Parameter List
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-3 Ext
end
ed F
unc
tion
Mod
e
4
4-
3-3 Gro
up C: Multi-
function
Ter
m
inal Fu
nction Par
ameters
*1. When the EDM function selector switch is ON, C021 is forcibly allocated to 62 (EDM). You cannot set 62 (EDM) manu-
ally. If you turn ON and then OFF the EDM function selector switch, C021 is set to 255 (no: No allocation).
The 3G3MX2-V1 Series Inverter is currently under application for safety standards.
Parameter
No.
Function
name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Multi-fu
nction in
put
termin
als
C011
Multi-function
Input S1 Oper-
ation Selection
00: NO (NO contact)
01: NC (NC contact)
00
Disabled
Enabled
−
P. 5-48
C012
Multi-function
Input S2 Oper-
ation Selection
00
Disabled
Enabled
C013
Multi-function
Input S3 Oper-
ation Selection
00
Disabled
Enabled
C014
Multi-function
Input S4 Oper-
ation Selection
00
Disabled
Enabled
C015
Multi-function
Input S5 Oper-
ation Selection
00
Disabled
Enabled
C016
Multi-function
Input S6 Oper-
ation Selection
00
Disabled
Enabled
C017
Multi-function
Input S7 Oper-
ation Selection
00
Disabled
Enabled
Multi-function
o
utp
ut termina
ls
C021
Multi-function
Output P1
Selection
00: RUN (Signal during RUN)
01: FA1 (Constant speed arrival signal)
02: FA2 (Set frequency exceeded signal)
03: OL (Overload warning)
04: OD (Excessive PID deviation)
05: AL (Alarm signal)
06: FA3 (Set-frequency only signal)
07: OTQ (Overtorque/Undertorque signal)
09: UV (Signal during undervoltage)
10: TRQ (Torque limit)
11: RNT (RUN time over)
12: ONT (Power ON time over)
13: THM (Electronic thermal warning)
19: BRK (Brake release)
20: BER (Brake error)
21: ZS (0-Hz detection signal)
22: DSE (Excessive speed deviation)
23: POK (Position ready)
24: FA4 (Set frequency exceeded signal 2)
25: FA5 (Set-frequency only signal 2)
26: OL2 (Overload warning 2)
27: FVDc (Analog FV disconnection detection)
28: FIDc (Analog FI disconnection detection)
31: FBV (PID feedback comparison signal)
32: NDc (Communications disconnection
detection)
33: LOG1 (Logic operation output 1)
34: LOG2 (Logic operation output 2)
35: LOG3 (Logic operation output 3)
39: WAC (Capacitor life warning signal)
40: WAF (Cooling fan life warning signal)
41: FR (Starting contact signal)
42: OHF (Cooling fin overheat warning)
43: LOC (Low current signal)
44: MO1 (General-purpose output 1)
45: MO2 (General-purpose output 2)
46: MO3 (General-purpose output 3)
50: IRDY (Operation ready)
51: FWR (Forward run signal)
52: RVR (Reverse run signal)
53: MJA (Fatal fault signal)
54: WCFV (Window comparator FV)
55: WCFI (Window comparator FI)
58: FREF (Frequency reference source)
59: REF (RUN command source)
60: SETM (Motor 2 selection)
62: EDM (Safety device monitor)
*1
63: OPO (Option)
255: no (No allocation)
00
(RUN)
Disabled
Enabled
−
P. 5-55
P. 7-20
C022
Multi-function
Output P2
Selection
01
(FA1)
Disabled
Enabled
C026
Multi-function
Relay Output
(MA, MB) Func-
tion Selection
05
(AL)
Disabled
Enabled
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...