6 - 47
6 Vector Control and Applied Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
6
-7 Sim
p
le Pos
ition
Co
ntro
l
6
6-
7-7 T
urnt
a
ble C
ontrol
This function is useful when using a system of rotating coordinates such as those of a turn table.
It performs positioning based on the amount of movement per rotation of the rotating coordinates in the
direction in which the moving distance is shorter.
• Set the Position Control Mode Selection (P075) to 01 (No limit).
• Set the amount of movement per rotation of the rotating coordinates in the Multi-step Position Com-
mand 0 (P060).
This value must be set as
×
1 multiplication pulses (equivalent the number of phase-A pulses) and a
positive value.
• In the Multi-step Position Command 1 to 7 (P061 to P067), set the actual target positions.
These values must be set as
×
1 multiplication pulses (equivalent the number of phase-A pulses).
• Because the Digital Operator of this inverter has a 4-digit display, you can set only the upper 4 digits.
To set a value over 4 digits, use the computer tool CX-Drive.
• This control is enabled when the Pulse Train Input Type Selection (P004) is set to 00 (Single-phase
pulse input) or 01 (Phase A and B 90° phase difference pulse train). Do not use this control with the
set value 03 (Single-phase pulse train
+
direction).
• The origin search, current position preset, and speed/position switching functions do not work when
the Position Control Mode Selection (P075) is set to 01 (No limit).
Do not use the turntable control function in conjunction with the origin search, current position preset,
or speed/position switching function.
6-7-7
Turntable Control
Parameter
No.
Function name
Data
Default
data
Unit
P075
Position Control
Mode Selection
00:
Limit
00
−
01:
No limit
P060
Multi-step Position
Command 0
Position Limit Setting (Reverse Side) (P073) to
Position Limit Setting (Forward Side) (P072)
(Displays upper 4 digits including “
−
”)
(
×
1 multiplication)
0
pulse
P061 to P067
Multi-step Position
Command 1 to 7
Position Limit Setting (Reverse Side) (P073) to
Position Limit Setting (Forward Side) (P072)
(Displays upper 4 digits including “
−
”)
(
×
1 multiplication)
0
pulse
P004
Pulse Train Input
Type Selection
00:
Single-phase pulse input
00
−
01:
Phase A and B 90°phase difference
pulse train
0
8000=P060
2000
4000
6000
P075=01
P075=00
If position command
value is 6000
(Shortest control path)
Current value
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...