6 Vector Control and Applied Functions
6 - 20
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
z
Recommended product
E6C3-CWZ5GH (Manufacturer: OMRON)
Additional Information
For pulse train input, use the pulse train input RP terminal and the multi-function Input S7 terminal of
the control circuit terminals.
Be sure to use a complementary-output type encoder.
Connect the Phase A and B 90°phase difference pulse train as shown in the diagram below.
• Connect the phase-A signal to the pulse train input terminal RP.
• Connect the phase-B signal to the multi-function Input S7 terminal and set the Multi-function Input S7
Selection (C007) to 85 (EB: Rotation direction detection).
• If the encoder signal is connected, you need to complete wiring for other multi-input terminals S1 to
S6 in the source logic (PNP).
• The control circuit terminal P24 of the inverter is for a 24-V, 100-mA max. power supply. It can be
used for the encoder power supply if the consumption current for the input terminals in use and the
encoder power supply is allowable. However, this terminal must be isolated from any 24-V system
power supply for other than the encoder and inverter.
Crosstalk : A phenomenon by which signals are erroneously transmitted between different
phases. Specifically, the rising/falling edge signal from phase A is superimposed on
the signal from phase B and the rising/falling edge signal from phase B is superim-
posed on the signal from phase A, respectively.
Encoder Input
Input signal type
Maximum Fre-
quency
Terminal RP
(5 to 24 VDC, 32 kHz max.)
Terminal S7/EB
(24 VDC, 1.8 kHz max.)
Single-phase pulse train (P004
= 00)
Terminal RP: 32 kHz
Terminal S7
(Terminal EB):
1.8 kHz
Single-phase pulse train
−
Phase A and B 90°phase differ-
ence pulse train (P004 = 01)
Phase-A pulse train
Phase-B pulse train
Single-phase pulse train
+
direc-
tion (P004 = 03)
Single-phase pulse train
Direction signal
*1
*1. Direction signal can be input in favor of the sink or source logic, independent of the output method of the en-
coder signal.
Wiring for Phase A and B 90°Phase Difference Pulse Train (P004 = 01)
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...