![Omron SYSDRIVE MX2 SERIES User Manual Download Page 247](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918247.webp)
6 - 5
6 Vector Control and Applied Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
6-1 Sen
sorless V
ect
or Co
ntro
l
6
6-
1-2 Of
fline Auto-
tuning
for Motor
Paramete
rs
Offline auto-tuning consists of the following five steps:
• Presetting of parameters
• Selection of motor rotation during auto-tuning
• Auto-tuning
• Operations after auto-tuning
• Operations in case of error
1
Presetting of parameters
(1) Set the 1st/2nd Motor Capacity (H003/H203) and the 1st/2nd Motor Pole Number
(H004/H204) according to your motor.
(2) Set the rated frequency of the motor in the 1st/2nd Base Frequency (A003/A203) and
set the rated voltage in the 1st/2nd Motor Rated Voltage Selection (A082/A282).
If the 1st/2nd Motor Rated Voltage Selection parameter does not provide data appropriate
to the rated voltage of your motor, select a slightly larger value than required and set the fol-
lowing value in the 1st/2nd Output Voltage Gain (A045/A245):
[1st/2nd Output Voltage Gain (A045/A245)] = 100%
×
[motor rated voltage]/[1st/2nd
Motor Rated Voltage Selection (A082/A282)]
(3) Set the DC Injection Braking Selection (A051) and Simple Position Control Selection
(P012) to 00 (Disabled).
If the DC Injection Braking Selection (A051) or Simple Position Control Selection (P012) is
set to 02 (Enabled), change it to 00 (Disabled). If either of these parameters is set to 02
(Enabled), auto-tuning will not be completed.
(4) Set the motor cable length in the Motor Cable Length (b033).
In the Motor Cable Length (b033), set the length of your motor cable.
(5) Do not to turn ON the torque reference input permission terminal (52: ATR).
Setting one of the Multi-function Input S1 to S7 Selection (C001 to C007) to 52 (ATR:
Torque reference input permission) prevents correct tuning data measurement if the corre-
sponding terminal is ON.
Offline Auto-Tuning Steps
Parameter
No.
Function name
Data
Default
data
Unit
H003/H203 1st/2nd Motor Capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/4.0/5.5/7.5/
11.0/15.0/18.5
Maximum
applicable
motor
capacity
kW
H004/H204
1st/2nd Motor Pole
Number
2/4/6/8
10 to 488: Do not set.
4
pole
A003/A203
1st/2nd Base Frequency 30.0 to 1st/2nd Maximum Frequency (A004/A204)
60.0
Hz
A045/A245
1st/2nd Output Voltage
Gain
20. to 100.
100.
%
A051
DC Injection Braking
Selection
00:
Disabled
00
−
A082/A282
1st/2nd Motor Rated
Voltage Selection
200-V class: 200 V/215 V/220 V/230 V/240 V
200/400
V
400-V class: 380 V/400 V/415 V/440 V/460 V/480 V
P012
Simple Position Con-
trol Selection
00:
Simple position control disabled
00
−
b033
Motor Cable Length
5. to 20.
10.
m
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...