![Omron SYSDRIVE MX2 SERIES User Manual Download Page 246](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918246.webp)
6 Vector Control and Applied Functions
6 - 4
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
• Use this function to measure and automatically set the motor parameters required for sensorless
vector control.
• To use the sensorless vector control method, perform auto-tuning to measure the motor parameter
values.
• The measured motor parameter values will be set as 50-Hz converted data for one phase in Y-con-
nection.
6-1-2
Offline Auto-tuning for Motor Parameters
Parameter
No.
Function name
Data
Default
data
Unit
H001
Auto-tuning Selection
00:
Disabled
00
−
01:
Enabled (No motor rotation)
02:
Enabled (Motor rotation)
H002/H202
1st/2nd Motor Parame-
ter Selection
00:
Standard motor parameter
00
−
02:
Auto-tuning parameter (Applies
H030/H230 to H034/H234 data to motor
parameters.)
H003/H203
1st/2nd Motor Capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/4.0/5.5/
7.5/11.0/15.0/18.5
Maximum
applicable
motor
capacity
kW
H004/H204
1st/2nd Motor Pole
Number
2/4/6/8
10 to 488: Do not set.
4
pole
H030/H230
1st/2nd Motor Parame-
ter R1 (Auto-tuning
Data)
0.001 to 9.999
10.00 to 65.53
Depen-
dent on
motor
capacity
Ω
H031/H231
1st/2nd Motor Parame-
ter R2 (Auto-tuning
Data)
H032/H232
1st/2nd Motor Parame-
ter L (Auto-tuning Data)
0.01 to 99.99
100.0 to 655.3
mH
H033/H233
1st/2nd Motor Parame-
ter lo (Auto-tuning
Data)
0.01 to 99.99
100.0 to 655.3
A
H034/H234
1st/2nd Motor Parame-
ter J (Auto-tuning Data)
0.001 to 9.999
10.00 to 99.99
100.0 to 999.9
1000. to 9999.
kgm
2
A003/A203
1st/2nd Base Frequency
30.0 to 1st/2nd Maximum Frequency
(A004/A204)
60.0
Hz
A051
DC Injection Braking
Selection
00:
Disabled
00
−
01:
Enabled
02:
Enabled (Operates only at set frequency)
A082/A282
1st/2nd Motor Rated
Voltage Selection
200-V class: 200/215/220/230/240
200/400
V
400-V class: 380/400/415/440/460/480
b033
Motor Cable Length
5. to 20.
10.
m
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...