10 Troubleshooting
10 - 8
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
Name
Description
Alarm
code
Check and remedy
Reference
page
Overload
protection in a
low speed
range
(Inverter
overload
protection)
The inverter trips if its built-in elec-
tronic thermal function detects an
overload in an extremely low speed
range of 0.2 Hz or lower. (However,
the error history may indicate a high
frequency.)
If the Motor Electronic Thermal Selec-
tion (b910) is set to separate the over-
load protection for the motor and for
the inverter, this function serves as
the inverter overload protection.
E38.
Is the load too heavy?
• Reduce the load rate.
P. 5-16
P. 5-60
P. 6-61
P. 7-35
P. 7-76
Digital
Operator
connection
failure
The inverter trips if an error or discon-
nection occurs when it communicates
with the external Digital Operator
(optional).
E40.
Is there any communications
error?
• Check/replace the cable.
This error detection function
is disabled when b165 is set
to 02 (Ignore).
P. 7-56
Modbus
communication
error
The inverter trips if a timeout occurs
when the Operation Selection on
Communication Error (C076) is set to
00 (Trip).
E41.
Is the communication speed cor-
rect?
• Check the set value.
Is the wiring distance appropri-
ate?
• Check the communications
wires.
Is there any disconnected wire?
• Check the wiring.
P. 8-5
DriveProgramming
error
• Program error (E43.
to E45.
)
• User trip (E50.
to E59.
)
E43.
to
E59.
For details, refer to the DrivePro-
gramming User's Manual.
−
Option error
This error is received from the option
unit.
E60.
to
E68.
For details, refer to the manual
for the option unit.
P. 10-10
Option timeout The inverter trips if a timeout occurs in
communications between the inverter
and the option unit.
E69.
No option unit is connected.
• Check that the housing of the
option unit is mounted prop-
erly with the inverter. Check
also that the fixation screws
are not loosened.
The option unit is faulty.
• The option unit may be faulty
if it is mounted properly.
P. 10-10
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...