4 - 9
4 Parameter List
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-3 Ext
end
ed F
unc
tion
Mod
e
4
4-
3-1 Gro
up A: S
ta
ndard F
unction Par
ameter
s
*1. The default data was changed from the previous model.
*2. Sensorless vector control can be set in the heavy load mode only.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
V/f characteristics
A041
1st Torque Boost
Selection
00: Manual
torque
boost
01
*1
Disabled Disabled
−
P. 5-60
01: Automatic
torque
boost
A241
2nd Torque Boost
Selection
00: Manual
torque
boost
01
*1
Disabled Disabled
−
01: Automatic
torque
boost
A042
1st Manual Torque
Boost Voltage
0.0 to 20.0 (Percentage of 1st Motor
Rated Voltage Selection (A082))
1.0
Enabled
Enabled
%
A242
2nd Manual Torque
Boost Voltage
0.0 to 20.0 (Percentage of 2nd
Motor Rated Voltage Selection
(A282))
1.0
Enabled
Enabled
%
A043
1st Manual Torque
Boost Frequency
0.0 to 50.0 (Percentage of 1st Base
Frequency (A003))
5.0
Enabled
Enabled
%
A243
2nd Manual Torque
Boost Frequency
0.0 to 50.0 (Percentage of 2nd Base
Frequency (A203))
5.0
Enabled
Enabled
%
A044
1st Control Method
00: Constant
torque
characteris-
tics (VC)
00
Disabled Disabled
−
P. 5-9
01: Reduced torque characteristics (VP
1.7th power (VC at low speed))
02: Free V/f setting
03: Sensorless vector control
*2
A244
2nd Control Method
00: Constant torque characteristics (VC)
00
Disabled Disabled
−
01: Reduced torque characteristics (VP
1.7th power (VC at low speed))
02: Free V/f setting
03: Sensorless vector control
*2
A045
1st Output Voltage
Gain
20. to 100.
100.
Enabled
Enabled
%
P. 7-41
A245
2nd Output Voltage
Gain
20. to 100.
100.
Enabled
Enabled
%
A046
1st Automatic Torque
Boost Voltage Com-
pensation Gain
0. to 255.
100.
Enabled
Enabled
−
P. 5-60
A246
2nd Automatic Torque
Boost Voltage Com-
pensation Gain
0. to 255.
100.
Enabled
Enabled
−
A047
1st Automatic
Torque Boost Slip
Compensation Gain
0. to 255.
0.
*1
Enabled
Enabled
−
A247
2nd Automatic
Torque Boost Slip
Compensation Gain
0. to 255.
0.
*1
Enabled
Enabled
−
DC in
jection
bra
king
A051
DC Injection Brak-
ing Selection
00: Disabled
00
Disabled
Enabled
−
P. 7-91
01: Enabled
02: Enabled (Operates only at set
frequency)
A052
DC Injection Brak-
ing Frequency
0.00 to 60.00
0.50
Disabled
Enabled
Hz
A053
DC Injection Brak-
ing Delay Time
0.0 to 5.0
0.0
Disabled
Enabled
s
A054
DC Injection Brak-
ing Power
0. to 100./70.
(Heavy load/Light load)
50.
Disabled
Enabled
%
A055
DC Injection Brak-
ing Time
0.0 to 60.0
0.5
Disabled
Enabled
s
A056
DC Injection Braking
Edge/Level Selection
00: Edge
operation
01
Disabled
Enabled
−
01: Level
operation
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...