5-6 A
ccelerati
on/D
eceleratio
n T
im
e Sett
ing
s
5
5-
6-3 2-
ste
p Acceleration/Deceleration Fu
nction
• Use the 2-step acceleration/deceleration function to switch between two acceleration/deceleration
time settings or change the acceleration/deceleration time on the way during acceleration/decelera-
tion.
• The acceleration/deceleration time switching method can be selected from the following three.
• A094/A294 = 00: Switch via 2CH terminal (multi-function input set to 09) (Example 1)
• A094/A294 = 01: Switch by 2-step Acceleration/Deceleration Frequency (A095/A295/A096/A296)
(Example 2)
• A094/A294 = 02: Switch only during forward/reverse switching (Example 3)
• To switch via a multi-function input terminal, set one of the parameters C001 to C007 to 09 (2CH).
*1. To enable the switching to the 2nd Acceleration/Deceleration Time 2 and to 2nd 2-step Acceleration/Deceler-
ation Frequency, set one of the Multi-function Input S1 to S7 Selection (C001 to C007) to 08 (SET) and turn
ON that terminal.
5-6-3
2-step Acceleration/Deceleration Function
Parameter
No.
Function name
Data
Default
data
Unit
A092
1st Acceleration Time 2
0.00 to 99.99
100.0 to 999.9
1000. to 3600.
10.00
s
A292
2nd Acceleration Time 2
*1
A093
1st Deceleration Time 2
0.00 to 99.99
100.0 to 999.9
1000. to 3600.
10.00
s
A293
2nd Deceleration Time 2
*1
A094
1st 2-step Acceleration/Deceleration
Selection
00: Switch via 2CH terminal
(multi-function input: 09)
(Example 1)
00
−
A294
2nd 2-step Acceleration/Deceleration
Selection
*1
01:
Switch by setting
(A095/A295/A096/A296)
(Example 2)
02:
Switch only during for-
ward/reverse switching
(Example 3)
A095
1st 2-step Acceleration Frequency
0.00 to 99.99
100.0 to 400.0
0.00
Hz
A295
2nd 2-step Acceleration Frequency
*1
A096
1st 2-step Deceleration Frequency
0.00 to 99.99
100.0 to 400.0
0.00
Hz
A296
2nd 2-step Deceleration Frequency
*1
Related functions
F002, F202, F003, F203, C001 to C007
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...