![Omron SYSDRIVE MX2 SERIES User Manual Download Page 137](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918137.webp)
4 - 3
4 Parameter List
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-1 Mo
nit
o
r Mod
e
4
4-
1-1 Gro
up d
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
*2. These parameters are newly added to the 3G3MX2-V1 Series.
Parameter
No.
Function name
Monitor or data range
Default
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
d008
Real Frequency
Monitor
−
400. to
−
100.
*1
−
99.9 to
−
10.0
−
9.99 to 99.99
100.0 to 400.0
*1
−
−
−
Hz
P. 7-7
d009
Torque Reference
Monitor
−
200. to 200.
−
−
−
%
P. 7-7
d010
Torque Bias Monitor
−
200. to 200.
−
−
−
%
P. 7-8
d012
Output Torque
Monitor
−
200. to 200.
−
−
−
%
P. 7-8
d013
Output Voltage
Monitor
0.0 to 600.0
−
−
−
V
P. 7-8
d014
Input Power Monitor 0.0 to 100.0
−
−
−
kW
P. 7-9
d015
Integrated Power
Monitor
0.0 to 999.9
1000. to 9999.
1000 to 9999 (10000 to 99990)
Γ
100 to
Γ
999 (100000 to 999000)
−
−
−
−
P. 7-9
d016
Total RUN Time
Monitor
0. to 9999.
1000 to 9999 (10000 to 99990)
Γ
100 to
Γ
999 (100000 to 999000)
−
−
−
h
P. 7-10
d017
Total Power ON
Time Monitor
0. to 9999.
1000 to 9999 (10000 to 99990)
Γ
100 to
Γ
999 (100000 to 999000)
−
−
−
h
P. 7-10
d018
Fin Temperature
Monitor
−
20.0 to 150.0
−
−
−
°C
P. 7-10
d022
Life Assessment
Monitor
1: Capacitor on main circuit board
2: Cooling fan
−
−
−
−
P. 7-11
d023
Program Counter
*2
(DriveProgramming)
0. to 1024.
−
−
−
−
P. 7-11
d024
Program Number
Monitor
*2
(DriveProgramming)
Always displays 1
−
−
−
−
−
d025
User Monitor 0
*2
(DriveProgramming) Displays DriveProgramming exe-
cution result.
−
2147483647 to 2147483647
(Displays upper 4digits including
“
−
”)
−
−
−
−
P. 7-11
d026
User Monitor 1
*2
(DriveProgramming)
d027
User Monitor 2
*2
(DriveProgramming)
d029
Position Com-
mand Monitor
−
268435455 to 268435455
(
×
1 multiplication)
(Displays upper 4digits including “
−
”)
−
−
−
pulse
P. 7-12
d030
Current Position
Monitor
−
268435455 to 268435455
(
×
1 multiplication)
(Displays upper 4digits including “
−
”)
−
−
−
pulse
P. 7-12
d050
Dual User Monitor
(2 types of data)
Displays data set in b160 and
b161.
−
−
−
−
P. 7-13
d060
Inverter Mode
Monitor
Displays the currently set mode.
*1
I-C (IM motor heavy load)
I-V (IM motor light load)
P (PM motor mode)
−
−
−
−
P. 7-13
2
1
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...