1 Overview
1 - 26
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
This inverter has the built-in DriveProgramming function as a simple sequence function.
This enables a stand-alone inverter to perform simple sequence control.
You can create programs easily in flowchart or text language method by using the CX-Drive.
For details, refer to “DriveProgramming User’s Manual (I580)”.
This inverter has a function to be able to set up to 10 register addresses.
For example, when designing replacement, you can match the inverter-side register addresses without
changing the communications program.
It is also possible to set the data type, scale, and endian (byte order) of communication data according
to the application.
The conventional electronic thermal function is used in common for both the inverter and the motor.
This time, the electric thermal function is separated for the motor and has additional functions to be able
to set electronic thermal characteristics according to the characteristics of the motor in use.
The inverter has an additional function to restart the optional equipment when the inverter parameters
are initialized or the reset signal is input.
Although, the lower limit of the pulse train input function is conventionally fixed, it is modified so that the
user can adjust this value according to the application. This is useful for the adjustment of the operating
range by the pulse train input and as a countermeasure against noise.
The 3G3MX2-V1 Series Inverter is currently under application for safety standards.
If your application requires compliance with safety standards, please use the conventional 3G3MX2
Series Inverters.
The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
With the 3G3MX2-V1 Series Inverter, you cannot use the high-frequency mode from now on.
DriveProgramming Function
Modbus Mapping Function
Changes of Electronic Thermal Function
Addition of Optional Equipment Restart Function at Initialization and
Reset Input
Addition of Pulse Train Frequency Input Lower Limit Parameter
Safety Function (Under Application for Standards)
Elimination of High-frequency Mode
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...