![Omron SYSDRIVE MX2 SERIES User Manual Download Page 525](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918525.webp)
10 - 9
10 Troubleshooting
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
10-
1 Alarm
Displ
ay and
Rem
e-
di
es
10
1
0-1-2
Alar
m Code List
Encoder
disconnection
The inverter trips, when the output fre-
quency is at the Creep Speed Setting
(P015) or higher, if the motor rotation
speed detected by the encoder
remains lower than the Starting Fre-
quency (b082) for the duration set in
the Encoder Disconnection Detection
Time (P077
≠
0) or longer.
E80.
The encoder wiring is discon-
nected or connected improperly.
• Check the encoder wiring.
The actual motor rotation speed
remains lower than the Starting
Frequency (b082) for the duration
set in the Encoder Disconnection
Detection Time (P077) or longer.
• Adjust the parameter values.
Set a slightly longer time in
P077 and a slightly higher
value in P015.
This alarm also occurs if the
motor rotation speed drops to
lower than the Starting Frequency
under simple position control.
• Adjust the parameter values.
Set a slightly longer time in
P077 and a slightly higher
value in P015.
P. 6-18
P. 6-28
Overspeed
The inverter trips if the motor rotation
speed exceeds the value set in Maxi-
mum Frequency
×
Overspeed Error
Detection Level (P026
≠
0).
E81.
This alarm is displayed based on
the speed detected by the
encoder.
The encoder wiring is discon-
nected or connected improperly.
• Check the encoder wiring.
The Number of Encoder Pulses
does not match.
• Check the number of
encoder pulses. (P011)
The actual motor speed is higher
than the error detection level.
• Adjust the Overspeed Error
Detection Level (P026) set-
ting.
P. 6-18
P. 6-28
Position
control range
trip
The inverter trips if the current posi-
tion is out of the range set in the Posi-
tion Limit Setting (P072, P073) during
simple position control.
E83.
Check the current position.
• Check the parameter settings
(P072, P073).
• Check the origin.
P. 6-34
Name
Description
Alarm
code
Check and remedy
Reference
page
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...