![Omron SYSDRIVE MX2 SERIES User Manual Download Page 60](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918060.webp)
1 Overview
1 - 28
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
For the following parameters, the setting range is changed to expand the range of supported applications.
Some parameter names were changed from the conventional 3G3MX2 Series.
The parameter number of each function is not changed, the same as before. Refer to
Section 4 Param-
eter List
. Some examples follow.
Changes of Parameter Setting Range
Parameter
No.
Parameter name
Data range
Previous model
3G3MX2-V1
F002
1st Acceleration Time 1
0.01 to 3600.00 s
0.00 to 3600.00 s
F202
2nd Acceleration Time 1
F003
1st Deceleration Time 1
F203
2nd Deceleration Time 2
A092
1st Acceleration Time 2
A292
2nd Acceleration Time 2
A093
1st Deceleration Time 2
A293
2nd Deceleration Time 2
A001
1st Frequency Reference
Selection
00 to 04, 06, 10
00 to 04, 06, 07, 10
A201
2nd Frequency Reference
Selection
00 to 04, 06, 10
00 to 04, 06, 07, 10
b027
Overcurrent Suppression
Selection
00, 01
00, 01, 02
b082
Starting Frequency
0.10 to 9.99 Hz
0.01 to 9.99 Hz
b084
Initialization Selection
00 to 03
00 to 03, 04
b120
Brake Control Function Selec-
tion
00, 01
00, 01, 02
b171
Inverter Mode Selection
00 to 02
00, 01, 03
C001 to
C007
Multi-function Input S1 to S7
Selection
00 to 09, 11 to 16, 18 to 24, 27 to
29, 31 to 42, 44, 46, 47, 50 to 53,
65 to 70, 73, 77, 78, 81, 83 to 86
255: no
00 to 09, 11 to 16, 18 to 24, 27 to
29, 31 to 42, 44, 46, 47, 50 to 53,
56 to 62, 65 to 70, 73, 77, 78, 81,
82, 83 to 86, 91
255: no
C021,
C022
Multi-function Output P1, P2
Selection
00 to 07, 09 to 13, 19 to 28, 31 to
35, 39 to 43, 50 to 55, 58 to 60,
62, 63
25: no
00 to 07, 09 to 13, 19 to 28, 31 to
35, 39 to 43, 44 to 46, 50 to 55,
58 to 60, 62, 63
255: no
C026
Multi-function Relay Output
(MA, MB) Function Selection
C027
MP Selection
00 to 08, 10, 15, 16
00 to 08, 10, 12, 15, 16
C028
AM Selection
00 to 02, 04 to 07, 10, 11, 16
00 to 02, 04 to 07, 10, 11, 13, 16
P003
Pulse Train Input RP Selec-
tion
00, 01
00, 01, 02
P031
Acceleration/Deceleration
Time Input Type
00
00, 03
Changes of Parameter Name
Parameter
No.
Parameter name
Previous model
3G3MX2-V1
b050
Controlled Deceleration on Power Loss
Deceleration Stop Selection on Power Interruption
b150
Main Panel Display Selection
Inverter Display on Operator Connection
b160
d050 Monitor Target 1
User Monitor Selection 1
C038
Low Current Signal Output Mode Selection
Low Current Signal Output Selection
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...