4 Parameter List
4 - 10
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
DC in
jection
bra
king
A057
Startup DC Injec-
tion Braking Power
0. to 100./70.
(Heavy load/Light load)
0.
Disabled
Enabled
%
P. 7-91
A058
Startup DC Injection
Braking Time
0.0 to 60.0
0.0
Disabled
Enabled
s
A059
DC Injection Brak-
ing Carrier Fre-
quency
2.0 to 15.0/10.0
(Heavy load/Light load)
5.0/
2.0
Disabled
Enabled
kHz
Li
mi
t, jump
A061
1st Frequency
Upper Limit
0.00
1st Frequency Lower Limit to 1st
Maximum Frequency
0.00
Disabled
Enabled
Hz
P. 5-31
A261
2nd Frequency
Upper Limit
0.00
2nd Frequency Lower Limit to 2nd
Maximum Frequency
0.00
Disabled
Enabled
Hz
A062
1st Frequency
Lower Limit
0.00
Starting Frequency to 1st Frequency
Upper Limit
0.00
Disabled
Enabled
Hz
A262
2nd Frequency
Lower Limit
0.00
Starting Frequency to 2nd Frequency
Upper Limit
0.00
Disabled
Enabled
Hz
A063
Jump Frequency 1
0.00 to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
P. 7-36
A064
Jump Frequency
Width 1
0.00 to 10.00
*1
0.50
Disabled
Enabled
Hz
A065
Jump Frequency 2
0.00 to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
A066
Jump Frequency
Width 2
0.00 to 10.00
*1
0.50
Disabled
Enabled
Hz
A067
Jump Frequency 3
0.00 to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
A068
Jump Frequency
Width 3
0.00 to 10.00
*1
0.50
Disabled
Enabled
Hz
A
cceleration stop
A069
Acceleration Stop
Frequency
0.00 to Starting Frequency: Disabled
Frequency above Starting Frequency
to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
P. 7-37
A070
Acceleration Stop
Time
0.0: Disabled
0.0
Disabled
Enabled
s
0.1 to 60.0
PID Braking
A071
PID Selection
00: Disabled
00
Disabled
Enabled
−
P. 7-44
01: Enabled
02: Enabled (Reverse output enabled)
A072
PID P Gain
0.00 to 25.00
1.00
Enabled
Enabled
−
A073
PID I Gain
0.0 to 999.9
1000. to 3600.
1.0
Enabled
Enabled
s
A074
PID D Gain
0.00 to 99.99
100.0
0.00
Enabled
Enabled
s
A075
PID Scale
0.01 to 99.99
1.00
Disabled
Enabled
time
A076
PID Feedback
Selection
00: FI
(Current)
00
Disabled
Enabled
−
01: FV
(Voltage)
02: Modbus
communication
03: Pulse train frequency
10: Operation
function
output
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...