![Omron SYSDRIVE MX2 SERIES User Manual Download Page 293](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918293.webp)
6 - 51
6 Vector Control and Applied Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
6
-7 Sim
p
le Pos
ition
Co
ntro
l
6
6-
7-9 Inte
rlo
ck Fun
ction with Simp
le Position C
ontrol and Br
ake C
ontrol
This section describes the settings related to the interlock function with simple position control and
brake control.
For the simple position control settings, refer to
6-7-3 Simple Position Control Operation and Settings
on page 6-34.
• Set the Simple Position Control Selection (P012) to 02 (Simple position control enabled) and, at the
same time, set the Brake Control Function Selection (b120) to 01 (Enabled: DC Injection Braking
enabled during stop) or 02 (Enabled: DC Injection Braking disabled during stop).
• The interlock function with simple position control and brake control is enabled only for the 1st control
method.
• Allocate one of the Multi-function Output P1/P2 Selection (C021/C022), or Multi-function Relay Out-
put (MA, MB) Function Selection (C026), to the following output signals.
• As required, set one of the Multi-function Input S1 to S7 Selection (C001 to C007) to 44 (BOK: Brake
confirmation).
• According to your system, set the parameters used for the operation sequence as shown in the table
below.
• It is recommended to use sensorless vector control (A044 = 03) that generates a high torque during
startup. For details, refer to
6-1 Sensorless Vector Control
on page 6-3.
• Set a frequency higher than the Creep Speed Setting (P015). If the set frequency is equal to or lower
than the P015 value, the inverter will detect an overload because the brake cannot be released.
Settings of Interlock Function with Simple Position Control and
Brake Control
Brake control output : 19 (BRK: Brake release)
Brake error output
: 20 (BER: Brake error)
Parameter
No.
Function name
Data
Default
data
Unit
P012
Simple Position Control
Selection
02:
Simple position control enabled
00
−
P014
Creep Speed Moving
Amount
0.0 to 400.0
Adjust the amount of movement in consider-
ation of the stopping accuracy, with the brake
application timing.
125.0
%
P015
Creep Speed Setting
*1
Starting Frequency to 10.00
Set the frequency for releasing/forcing the
brake.
This setting is also used for the creep speed
under simple position control.
5.00
Hz
P017
Positioning Completion
Range Setting
0 to 10000 (
×
4 multiplication)
Set the output range of the positioning com-
pletion signal in consideration of the Creep
Speed Moving Amount.
50.
pulse
b120
Brake Control Function
Selection
01:
Enabled (DC injection braking enabled
during stop)
*2
00
−
02:
Enabled (DC injection braking disabled
during stop)
b121
Brake Release Wait
Time
0.00 to 5.00
The time from when the inverter reaches the
frequency set in the Creep Speed Setting until
it outputs the brake release signal. Set the
time until the output current reaches the
Brake Release Current value.
0.00
s
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...