![Omron SYSDRIVE MX2 SERIES User Manual Download Page 146](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918146.webp)
4 Parameter List
4 - 12
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
*2. This setting is enabled when the Digital Operator with the volume control (Model: 3G3AX-OP01) is connected.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Freq
uency adj
ustme
nt A101
FI Start Frequency
0.00 to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
P. 7-25
A102
FI End Frequency
0.00
Disabled
Enabled
A103
FI Start Ratio
0. to FI End Ratio
20.
Disabled
Enabled
%
A104
FI End Ratio
FI Start Ratio to 100
100.
Disabled
Enabled
%
A105
FI Start Selection
00: FI Start Frequency (A101)
00
Disabled
Enabled
−
01: 0
Hz
Acceleratio
n/Decelerati
on A131 Acceleration Curve
Parameter
01 (Small curve) to 10 (Large curve)
02
Disabled
Enabled
−
P. 5-34
A132
Deceleration Curve
Parameter
02
Disabled
Enabled
Calcu
lation
frequ
ency
A141
Calculation Fre-
quency Selection 1
00: Digital Operator (A020/A220)
02
Disabled
Enabled
−
P. 7-39
01: Digital Operator (Volume)
*2
02: Input FV (Voltage)
A142
Calculation Fre-
quency Selection 2
03: Input FI (Current)
03
Disabled
Enabled
04: Modbus
communication
05: Option
07: Pulse train frequency
A143
Calculation Function
Operator Selection
00: Addition
(A141
+
A142)
00
Disabled
Enabled
−
01: Subtract
ion
(A141
−
A142)
02: Multiplication
(A141
×
A142)
A145
Frequency Addi-
tion Amount Set-
ting
0.00 to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
P. 7-39
A146
Frequency Addition
Sign Selection
00: Frequency
reference
+
A145
00
Disabled
Enabled
−
01: Frequency
reference
−
A145
Acceler
a
tion/Deceleration
A150
EL-S Shape Accel-
eration Curve Ratio
1
0. to 50.
10.
Disabled Disabled
%
P. 5-34
A151
EL-S Shape Accel-
eration Curve Ratio
2
10.
Disabled Disabled
A152
EL-S Shape Decel-
eration Curve Ratio
1
10.
Disabled Disabled
A153
EL-S Shape Decel-
eration Curve Ratio
2
10.
Disabled Disabled
Deceleration stop
A154
Deceleration Stop
Frequency
0.00 to Starting Frequency: Disabled
Frequency above Starting Frequency
to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
P. 7-37
A155
Deceleration Stop
Time
0.0: Disabled
0.0
Disabled
Enabled
s
0.1 to 60.0
PID
A156
PID Sleep Opera-
tion Level
0.00 to 99.99
100.0 to 400.0
*1
0.00
Disabled
Enabled
Hz
P. 7-44
A157
PID Sleep Opera-
tion Delay Time
0.0 to 25.5
0.0
Disabled
Enabled
s
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...