![Omron SYSDRIVE MX2 SERIES User Manual Download Page 190](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918190.webp)
5 Basic Settings
5 - 14
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
In the light load mode, the following parameters are not displayed.
b083
Carrier
Frequency
2.0 to 15.0 [kHz]
2.0 to 10.0 [kHz]
10.0 [kHz]
2.0 [kHz]
Enabled
Disabled
C030
Digital Current
Monitor Refer-
ence Value
0.20
×
Heavy-load rated
current to 2.00
×
Heavy-load
rated current [A]
0.20
×
Light-load rated
current to 1.50
×
Light-load
rated current [A]
Heavy-
load rated
current [A]
Light-load
rated
current [A]
Conversion
*1
Conversion
*1
C039
Low Current
Detection Level
0.00 to 2.00
×
Heavy-load
rated current [A]
0.00 to 1.50
×
Light-load
rated current [A]
Heavy-
load rated
current [A]
Light-load
rated
current [A]
Conversion
*1
Conversion
*1
C041
1st Overload
Warning Level
0.00:
Overload warning
detection disabled
0.00:
Overload warning
detection disabled
1.15
×
Heavy-load
rated
current [A]
1.15
×
Light-load
rated
current [A]
Conversion
*1
Conversion
*1
0.01 to 2.00
×
Heavy-load
rated current [A]
0.01 to 1.50
×
Heavy-load
rated current [A]
C241
2nd Overload
Warning Level
C111
1st Overload
Warning Level 2
0.00:
Overload warning
detection disabled
0.00:
Overload warning
detection disabled
1.15
×
Heavy-
load rated
current [A]
1.15
×
Light-load
rated
current [A]
Conversion
*1
Conversion
*1
0.01 to 2.00
×
Heavy-load
rated current [A]
0.01 to 1.50
×
Light-load
rated current [A]
H003
1st Motor
Capacity
0.1 to 18.5 [kW]
Setting in steps
*2
Same as the setting range for
heavy load mode
Max.
applicable
motor
capacity for
heavy load
[kW]
Max.
applicable
motor
capacity for
light load
[kW]
Disabled
Disabled
H203
2nd Motor
Capacity
*1. Conversion: The set current value will be converted at the ratio of the rated current for the heavy load/light load mode.
(Example) If you change from a light load mode setting of 5 A (rated current: 10 A) to the heavy load mode (rated current:
8 A), the current value will be converted as follows: Rated current 8A
×
50% (5 A/10 A) = 4 A.
*2. Setting in steps: Steps of 0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/4.0/5.5/7.5/11.0/15.0/18.5 [kW] can be selected.
Parameter No.
Function name
Parameter No.
Function name
d009
Torque Reference Monitor
H005/H205
1st/2nd Speed Response
d010
Torque Bias Monitor
H020/H220
1st/2nd Motor Parameter R1
d012
Output Torque Monitor
H021/H221
1st/2nd Motor Parameter R2
b040
Torque Limit Selection
H022/H222
1st/2nd Motor Parameter L
b041
Torque Limit 1
(Four-quadrant Mode Forward
Power Running)
H023/H223
1st/2nd Motor Parameter Io
b042
Torque Limit 2
(Four-quadrant Mode Reverse
Regeneration)
H024/H224
1st/2nd Motor Parameter J
b043
Torque Limit 3
(Four-quadrant Mode Reverse
Power Running)
H030/H230
1st/2nd Motor Parameter R1
(Auto-tuning Data)
b044
Torque Limit 4
(Four-quadrant Mode Forward
Regeneration)
H031/H231
1st/2nd Motor Parameter R2
(Auto-tuning Data)
b045
Torque LADSTOP Selection
H032/H232
1st/2nd Motor Parameter L
(Auto-tuning Data)
b046
Reverse Rotation Prevention Selec-
tion
H033/H233
1st/2nd Motor Parameter Io
(Auto-tuning Data)
C054
Overtorque/Undertorque Selection
H034/H234
1st/2nd Motor Parameter J
(Auto-tuning Data)
C055
Overtorque/Undertorque Level
(Forward Power Running)
P033
Torque Reference Input Selection
C056
Overtorque/Undertorque Level
(Reverse Regeneration)
P034
Torque Reference Setting
Para-
meter
No.
Function
name
Setting range
Default data
Initialization at
mode switching
Heavy load (CT)
Light load (VT)
Heavy
load (CT)
Light
load (VT)
Heavy to
Light
Light to
Heavy
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...