5 Basic Settings
5 - 60
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
5-11 Torque Boost Function Settings
• Use the torque boost function to raise the output torque if it is not sufficient at low speeds.
• This inverter provides two torque boost options: Manual torque boost for manual torque adjustment
and Automatic torque boost for automatic torque adjustment.
• In the 3G3MX2-V1 Series, the default data for A041/A241 were changed to Automatic torque boost.
(A041/A241 = 01)
• To use the automatic torque boost function effectively, be sure to set the 1st/2nd Motor Capacity
(H003/H203) and the 1st/2nd Motor Pole Number (H004/H204) according to your motor.
*1. To enable the switching to the 2nd control, allocate one of the Multi-function Input S1 to S7 Selection (C001 to
C007) to 08 (SET) and turn ON that terminal.
*2. Set data as a percentage (%) of the 1st/2nd Motor Rated Voltage Selection (A082/A282).
*3. Set data as a percentage (%) of the 1st/2nd Maximum Frequency (A004/A204).
*4. The default data was changed from the previous model.
5-11-1 Torque Boost
Parameter
No.
Function name
Data
Default data
Unit
A041
1st Torque Boost Selection
00: Manual torque boost
01
*4
−
A241
2nd Torque Boost Selection
*1
01: Automatic torque boost
A042
1st Manual Torque Boost Voltage
0.0 to 20.0
*2
1.0
%
A242
2nd Manual Torque Boost Voltage
*1
A043
1st Manual Torque Boost Frequency
0.0 to 50.0
*3
5.0
%
A243
2nd Manual Torque Boost Frequency
*1
H003
1st Motor Capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/
2.2/3.0/3.7/4.0/5.5/7.5/11.0/
15.0/18.5
Maximum
applicable
motor capacity
kW
H203
2nd Motor Capacity
*1
H004
1st Motor Pole Number
2/4/6/8
10 to 48: Do not set.
4
pole
H204
2nd Motor Pole Number
*1
A046
1st Automatic Torque Boost Voltage
Compensation Gain
0. to 255.
100.
%
A246
2nd Automatic Torque Boost Voltage
Compensation Gain
*1
A047
1st Automatic Torque Boost Slip
Compensation Gain
0. to 255.
0.
*4
A247
2nd Automatic Torque Boost Slip
Compensation Gain
*1
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...