![Omron SYSDRIVE MX2 SERIES User Manual Download Page 266](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918266.webp)
6 Vector Control and Applied Functions
6 - 24
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
You can adjust the V/f control with speed feedback function with the gain settings shown below.
However, the function cannot be adjusted when using a motor that causes an extremely large slip (10%
of the rated rotation speed or higher) or in applications where such a large load that causes the motor to
stall (or step out) is applied. If so, set the type and capacity of the motor again.
z
V/f Control With Speed Feedback Slip Compensation Proportional Gain
At first, adjust the proportional gain for speed feedback.
• In the Real Frequency Monitor (d008), check and gradually increase the set value.
• While checking the Real Frequency Monitor (d008), increase the value within the range where the
motor speed is stable.
• If the motor speed fluctuates or the motor vibrates wildly, decrease the set value until it becomes
stable.
• When adjusting the responsiveness if the load is actually activated, increase the set value to
improve it, or decrease the set value to make it stable.
z
V/f Control With Speed Feedback Slip Compensation Integral Gain
Next, adjust the integral time for speed feedback.
• In the Real Frequency Monitor (d008), check and gradually decrease the set value.
• Decrease the value in the Real Frequency Monitor (d008) until it matches the reference fre-
quency.
• If the motor speed fluctuates or the motor vibrates wildly, increase the set value until it becomes
stable.
• When adjusting the responsiveness if the load is actually activated, decrease the set value to
improve it, or increase the set value to make it stable.
6-5-4
Adjustments for V/f Control with Speed Feedback
Parameter No.
Function name
Data
Default
data
Unit
H050
V/f Control With Speed Feedback
Slip Compensation Proportional
Gain
0.00 to 10.00
0.20
Time
H051
V/f Control with Speed Feedback
Slip Compensation Integral Time
0. to 1000.
2.
s
Frequency reference
Proportional gain
(H050)
Integral gain
(H051)
Set frequency
(F001)
Speed feedback
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...