1 - 3
1 Overview
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
1-
1 Ov
er
v
iew o
f F
u
n
ction
s
1
1
-1-1
Featur
es o
f 3G3
M
X
2
-V1 Series Inve
rter
Precautions for Correct Use
Derating of the rated output current of the inverter may be required depending on the
heavy/light load mode selection, operating ambient temperature, side-by-side installation, and
carrier frequency settings.
Use the inverter in an appropriate environment according to
A-1 Derating
on page A-2.
z
Simple position control
This inverter provides simple position control that enables the control of up to 8 points with a single
inverter unit.
With the standard pulse train input function, it realizes accurate position control based on the feed-
back of the pulse generator (PG) signal or the encoder’s phase-A/B signal.
For enhancements, simple position control has the following additional functions this time. More-
over, it can be combined with control from the open field network to expand the control range of your
system.
z
Implementation of the programming function
The 3G3MX2-V1 Series has the buit-in simple sequence function (DriveProgramming), which
enables a stand-alone inverter to perform simple sequence control.
You can create programs easily in flowchart or text language method by using the CX-Drive.
For details, refer to “DriveProgramming User’s Manual (I580)”.
z
Sensorless vector control
This inverter provides the sensorless vector function and the auto-tuning function to achieve a high
starting torque of 200% at 0.5 Hz.
This enables powerful drive control even at low speeds.
In addition, sensorless vector control can be used in conjunction with the torque limit and torque
control functions.
It is applicable to device contact stopper, load breakage protector, and other control applications.
z
V/f control with speed feedback
With the standard pulse train input function, this inverter realizes accurate Vf control based on the
feedback of the pulse generator (PG) signal or the encoder’s phase-A/B signal.
The speed feedback capability ensures stable speed control at high accuracy.
z
PID control function
The inverter provides PID control that adjusts the feedback value to match the target value.
This is available to the process control such as temperature, pressure, flow rate.
• Restarting Positioning
: Repositions the motor to the target position if it is out of
the setting range.
• Position Store Selection at Power Off : Stores the current position at power off and resume from
the stored position at the next power-on.
• Preset Position
: Sets the current stop position as a preset position, for
example, after completion of an origin search.
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...