![Omron SYSDRIVE MX2 SERIES User Manual Download Page 497](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918497.webp)
8 - 85
8 Communications Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
8-9 Mo
db
us Co
mm
un
icatio
n Dat
a L
ist
s
8
8-9
-4 Group A/b
/C/H/P Register List
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1610 hex
−
Reserved
−
−
−
−
−
1611 hex
1610 hex
Positioning
Completion Range
Setting
P017
R/W 0 to 10000
1
[pulse]
P. 6-34
1612 to
1619 hex
−
Reserved
−
−
−
−
−
161A hex
1619 hex
Overspeed Error
Detection Level
P026
R/W 0 to 1500
0.1 [%]
P. 6-23
161B hex
161A hex
Speed Deviation
Excessive Level
P027
R/W 0 to 12000
0.01
[Hz]
161C to
161E hex
−
Reserved
−
−
−
−
−
161F hex
161E hex
Acceleration/
Deceleration Time
Input Type
P031
R/W
00:
Digital Operator
−
P. 5-33
03:
DriveProgramming
1620 hex
−
Reserved
−
−
−
−
−
1621 hex
1620 hex
Torque Reference
Input Selection
P033
R/W
00:
Terminal FV
−
P. 6-16
01:
Terminal FI
03:
Digital Operator
06:
Option (No applica-
ble Option)
1622 hex
1621 hex
Torque Reference
Setting
P034
R/W 0 to 200
1 [%]
1623 hex
−
Reserved
−
−
−
−
−
1624 hex
1623 hex
Torque Bias Selec-
tion
P036
R/W
00:
Disabled
−
P. 6-17
01:
Digital Operator
05:
Option (No applica-
ble Option)
1625 hex
1624 hex
Torque Bias Value
P037
R/W
−
200 to 200
1 [%]
1626 hex
1625 hex
Torque Bias Polarity
Selection
P038
R/W
00:
As per sign
−
01:
Dependent on
RUN direction
1627 hex
1626 hex
Speed Limit Value in
Torque Control
(Forward)
P039
(HIGH)
R/W
0 to 12000
0.01
[Hz]
P. 6-16
1628 hex
1627 hex
P039
(LOW)
R/W
1629 hex
1628 hex
Speed Limit Value in
Torque Control
(Reverse)
P040
(HIGH)
R/W
0 to 12000
0.01
[Hz]
162A hex
1629 hex
P040
(LOW)
R/W
162B hex
162A hex
Speed/Torque
Switching Time
P041
R/W 0 to 1000
1 [ms]
162C hex
−
Reserved
−
−
−
−
−
162D hex
162E hex
162D hex
Communications
Error Detection
Timer Setting
P044
R/W 0 to 9999
0.01 [s]
P. 7-101
162F hex
162E hex
Operation Selection
at Host
Communications
Error
P045
R/W
00:
Trip
−
P. 7-101
01:
Trip after decelera-
tion stop
02:
Ignore
03:
Free-run stop
04:
Deceleration stop
1630 hex
162F hex
Assembly Instance
Number
P046
R/W 0 to 20
−
P. 7-101
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...