NetBIOS Relays
Page 26-13
Configuring NBNS Relay
Each
NetBIOS
PC has a name unique for its local network. If you are using
NetBIOS
broadcast
queries to resolve names and
NetBIOS
clients are located in different groups or
VLANs
, you
should configure
UDP
relay for
NBNS
.
The relays are enabled from the UDP Relay Configuration screen and are configured in simi-
lar ways. The UDP Relay Configuration screen is displayed using the
relayc
command
described in
UDP Relay Configuration Screen
on page 26-3. To enable the
NBNS
relay, enter
2=y
. (To enable the NBDD relay, enter see
Configuring NBDD Relay
on page 26-16.)
The UDP Relay Configuration screen redisplays similar to the following:
UDP Relay Configuration
1) BOOTP/DHCP Enabled
: Yes
11) Server Address{list/add/delete}
: UNSET
12) Forward Delay
: 3
13) Maximum Hops
: 4
2) NBNS Enabled
: Yes
21) Next-hop Address {list/add/delete}
: UNSET
22) Forward to VLANs {list/add/delete}
: UNSET
3) NBDD Enabled
:No
4) +Generic Services Menu
Command {Item=Value/?/Help/Quit/Redraw/Save} (Redraw) :
Either a Next-hop Address
or
a Forward to VLANs value must be configured for the relay.
Next-hop Address
Use this parameter to list, add, or delete the server address(es) to which the
NBNS UDP
relay
will forward. The default is
UNSET.
The value redisplays as
SET
when at least one address is
configured. Up to 8 addresses may be configured. You can list, add, or delete addresses by
entering
21=l
,
21=a
, or
21=d
on the command line.
Forward to VLANs
Use this parameter to list, add, or delete
VLANs
to which the
NBNS UDP
relay will forward.
This default is
UNSET
. This value redisplays as
SET
when at least one
VLAN
is configured. Up
to 32
VLANs
may be configured. You can list forwarding
VLANs
, or add or delete
VLANs
from
the forwarding list by entering
22=l
,
22=a
, or
22=d
on the command line. Entries marked with
an asterisk indicate the
VLANs
to which the relay will forward.
Summary of Contents for Omni Switch/Router
Page 1: ...Part No 060166 10 Rev C March 2005 Omni Switch Router User Manual Release 4 5 www alcatel com ...
Page 4: ...page iv ...
Page 110: ...WAN Modules Page 3 40 ...
Page 156: ...UI Table Filtering Using Search and Filter Commands Page 4 46 ...
Page 164: ...Using ZMODEM Page 5 8 ...
Page 186: ...Displaying and Setting the Swap State Page 6 22 ...
Page 202: ...Creating a New File System Page 7 16 ...
Page 270: ...Displaying Secure Access Entries in the MPM Log Page 10 14 ...
Page 430: ...OmniChannel Page 15 16 ...
Page 496: ...Configuring Source Route to Transparent Bridging Page 17 48 ...
Page 542: ...Dissimilar LAN Switching Capabilities Page 18 46 ...
Page 646: ...Application Example DHCP Policies Page 20 30 ...
Page 660: ...GMAP Page 21 14 ...
Page 710: ...Viewing the Virtual Interface of Multicast VLANs Page 23 16 ...
Page 722: ...Application Example 5 Page 24 12 ...
Page 788: ...Viewing UDP Relay Statistics Page 26 24 ...
Page 872: ...The WAN Port Software Menu Page 28 46 ...
Page 960: ...Deleting a PPP Entity Page 30 22 ...
Page 978: ...Displaying Link Status Page 31 18 ...
Page 988: ...Displaying ISDN Configuration Entry Status Page 32 10 ...
Page 1024: ...Backup Services Commands Page 34 14 ...
Page 1062: ...Diagnostic Test Cable Schematics Page 36 24 ...
Page 1072: ...Configuring a Switch with an MPX Page A 10 ...
Page 1086: ...Page B 14 ...
Page 1100: ...Page I 14 Index ...