Connecting a DC Power Source to an OmniS/R-PS9-DC725
Page 1-28
Installing DC Power Source Wire Leads
These instructions describe how to connect your 3-wire DC power source to the power
connector on your DC power supply. A small flat-tip screwdriver and a wire stripper are
required for this procedure.
1.
Prepare the three (3) wires—10 gauge—that will plug into the power supply. First,
make
sure they are not plugged into the 48-volt power source.
2.
Next, use a wire stripper to carefully strip about a half-inch off the end of each wire,
removing the outer insulation to expose the copper core.
3.
Twist the loose strands of copper wire together so that they form a tight braid. If possi-
ble, solder the entire braid of wire together for better conductivity.
4.
Open the wire bay door for one of the three (3) power connector holes. The front of the
power connector contains a row of square holes. It also contains three (3) circular holes
(located directly above the square holes) that contain screws; you loosen the screws in
these holes to open the wire bay doors (square holes) on the connector front so that you
can insert the wire leads into the power connector.
a.
Insert a small flat-tip screwdriver into one of the three (3) screw holes.
b.
Loosen the screw so that the door for the wire bay on the connector front opens.
Opening Wire Bay on DC Power Supply Connector
5.
Insert the appropriate wire lead into the open circular hole. The silkscreen above each
hole indicates which power lead—ground (GND), positive (+), or negative (-)—to plug
into which hole. The lead you insert
must
match the lead attached to the 48-volt power
source (i.e., ground to ground, positive to positive, negative to negative).
♦
Warning
♦
You
must
plug DC wire leads into the correct holes in
the DC power connector. Use the labels above the DC
power connector as a guide to ground, positive and
negative connections.
If you plug wire leads into the wrong holes, the power
supply will not work and could result in damage.
Push the wire in far enough so that it reaches the back wall of the connector, about a half
inch inside.
Door inside square hole will
open when screw is loosened in
circular hole directly above it.
Loosen Screw.
GND/(+)/(-)
Summary of Contents for Omni Switch/Router
Page 1: ...Part No 060166 10 Rev C March 2005 Omni Switch Router User Manual Release 4 5 www alcatel com ...
Page 4: ...page iv ...
Page 110: ...WAN Modules Page 3 40 ...
Page 156: ...UI Table Filtering Using Search and Filter Commands Page 4 46 ...
Page 164: ...Using ZMODEM Page 5 8 ...
Page 186: ...Displaying and Setting the Swap State Page 6 22 ...
Page 202: ...Creating a New File System Page 7 16 ...
Page 270: ...Displaying Secure Access Entries in the MPM Log Page 10 14 ...
Page 430: ...OmniChannel Page 15 16 ...
Page 496: ...Configuring Source Route to Transparent Bridging Page 17 48 ...
Page 542: ...Dissimilar LAN Switching Capabilities Page 18 46 ...
Page 646: ...Application Example DHCP Policies Page 20 30 ...
Page 660: ...GMAP Page 21 14 ...
Page 710: ...Viewing the Virtual Interface of Multicast VLANs Page 23 16 ...
Page 722: ...Application Example 5 Page 24 12 ...
Page 788: ...Viewing UDP Relay Statistics Page 26 24 ...
Page 872: ...The WAN Port Software Menu Page 28 46 ...
Page 960: ...Deleting a PPP Entity Page 30 22 ...
Page 978: ...Displaying Link Status Page 31 18 ...
Page 988: ...Displaying ISDN Configuration Entry Status Page 32 10 ...
Page 1024: ...Backup Services Commands Page 34 14 ...
Page 1062: ...Diagnostic Test Cable Schematics Page 36 24 ...
Page 1072: ...Configuring a Switch with an MPX Page A 10 ...
Page 1086: ...Page B 14 ...
Page 1100: ...Page I 14 Index ...