2-597
詳細説明
MACHINE OPERATIONS
Display diagnostic screen.
Relay (KS14) or solenoid valve (YV81)
wiring disconnection?
Contact the Mori Seiki Service Department for assistance.
No
Confirm that the unclamp output signal (Y45) is ON
and unclamp completed (M1759) is Off.
Is the clamp completed
input signal (X4C) OFF on
the diagnostic screen?
Repair or
replace
damaged parts.
Confirm proximity
switch (SQ14)
operation, and adjust or
replace as necessary.
Recovery
No Recovery
No
Yes
Yes
Recovery
No Recovery
Relay (KS13) or solenoid valve (YV80)
wiring disconnection?
No
Confirm that the clamp output signal (Y44) is ON
and clamp completed (M1758) is Off.
Is the clamp completed
input signal (X4C) OFF on
the diagnostic screen?
Repair or
replace
damaged parts.
Confirm proximity
switch (SQ14)
operation, and adjust or
replace as necessary.
Recovery
No Recovery
No
Yes
Yes
Recovery
No Recovery