2-586
詳細説明
MACHINE OPERATIONS
Motor breaker (thermal relay) QM63 turned ON?
Pump motor not rotating.
Magnet switch ON?
Power supplied to motor?
200 V AC (DC) supplied to magnet switch lower terminal?
200 V AC (DC) supplied to magnet switch upper terminal?
Confirm 200 V supply (breaker).
Reset (turn ON) the motor breaker (thermal relay)
and check the result. If the error occurs again,
check the load on the motor.
Magnet switch motion-related 24 V AC (DC) supplied?
Confirm 24 V AC (DC) supply (circuit protector).
Magnet Switch Malfunction
Motor Malfunction
Magnet Switch Malfunction
Check wiring, connections between motor and
magnet switch.
No
No
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Yes
coolant button
[ON]
on the operation panel illuminated?
Operator door closed?
Machine in emergency stop condition?
Yes
No
Yes
No
Yes
No
Release emergency stop.
Close operator door.
No Recovery
No Recovery
Recovery
Summary of Contents for MSX-850