![EXFO Power Blazer 88200NGE User Manual Download Page 694](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938694.webp)
Test Functions
684
88000 Series
Packet Capture
Triggered Frame
-
Details
gives details on the triggered frame.
The triggered frame corresponds to the first received frame that
matches the filter and the trigger settings.
Frame Number
indicates the triggered frame position in the buffer.
The framing MAC/IP/UDP/TCP source and destination addresses are
displayed in a table.
Capture
button allows starting/stopping the data capture. The test
must be running (refer to
on page 741) in order to
start capturing and recording data into the buffer. The Capture button is
not available when the trigger on field match is selected while its
trigger parameters are not valid.
No data will be recorded in the buffer if no frame matches the filter and
the trigger criteria during the data capture.
The data capture stops automatically once the buffer is full. The
maximum buffer capacity is 64 KBytes or a maximum of 2078 frames
for rates up to 10GE and 512 KBytes or a maximum of 8192 frames for
rates 40GE and 100GE.
When the capture stops or is manually stopped, the following message
is displayed:
Capture completed. Press Export to save captured
data (the test must be stopped)
. To avoid losing the captured data,
the data must be exported and saved into a file before restarting the
test or creating a new test.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...