Test Setup - Test Configurator, Timer, and System
Power Blazer
365
TCP Throughput
TCP Throughput
From the
Test
menu, tap
Setup
,
Test Configurator
, and tap on the test
block.
TCP Mode
Since two units are required to perform a TCP Throughput test, one unit
must be the source (
Local
) unit and the other one the destination
(
Remote
). Set the TCP Mode on both units:
Local
(default) or
Remote
.
TCP Connection Configuration
Remote IP Address
, available with
Local
TCP mode, allows entering
the IP address of the remote unit.
Quick Ping
button automatically starts the quick Ping utility for the
remote IP address and provides either a successful or failed result. The
quick Ping uses 3 attempts, a Delay of 1 second, a Timeout of 2
seconds, and a Data Size of 32 Bytes. Refer to
Accept Connection from IP
, available with
Remote
TCP mode, allows
entering the IP address of the local unit. The IP address
0.0.0.0
(default) listens to any TCP stream.
IP TOS/DS
, available with
Local
TCP mode, is configurable from
0x00
(default) to
0xFF
.
TCP Port
, available with
Local
and
Remote
TCP modes, allows the
selection of the TCP port number:
0
to
65535
(default is
50201
). For the
local unit, the specified TCP port will be used for the TCP initialization
algorithm with the remote unit. The following TCP segments sent by
the local unit will use the TCP port number replied by the remote unit.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...