Test Results
584
88000 Series
Summary (SyncE)
ESMC
Indicates the current (meter and value), average, minimum, and
maximum ESMC frame rate (including information and event frames)
received in frame/s. A fail verdict is also displayed beside the minimum
and/or maximum values when the ESMC frame rate is outside the range
while the Pass/Fail Verdict is enabled.
ESMC RX Rate
meter displays the current ESMC frame rate (including
information and event frames) in frame/s averaged over the last 11 frames
received. The pass/fail verdict is also displayed when enabled.
Note:
When the
Pass/Fail Verdict
and
ESMC Rate Threshold
check boxes are
selected (see page
), the green region is delimited from 0.8 to 10.2
frames/s corresponding to a
PASS
verdict. The red regions above and
beyond the threshold correspond to a
FAIL
verdict. There is neither green
nor red region when the Pass/Fail verdict is disabled.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...