Test Results
494
88000 Series
Logger
Save to CSV
Allows saving the logger content to a CSV file format.
Table
The logger table provides the following event logger information.
ID
: Indicates the event identification number. The events are
sequentially numbered.
Start Time
: Indicates when the event has been started or detected.
Event
: Provides the event type and threshold crossing information.
Duration or End Time
, depending on the
Closure Format
selected,
indicates either the duration or at what time the event has been
completed or cleared.
Details
: Provides contextual information including the pass/fail verdict.
The following table displays the nature of information reported by type of
event:
Note:
The Logger table can display up to 5000 event entries. Once the Logger
table reports 5000 event entries, a log full indicator appears and no further
entries are possible. However, the events in the Pending state will be
updated if the test is still running.
Type of Event
Nature of Information
Test Started
Start Date
Test Stopped
Pass/Fail Verdict
Alarm Events
Count value
Error Events
Current Count and Total Count
SDT Events
Service Disruption Time
Threshold Crossing Event
Value at the end of the test
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...