![EXFO Power Blazer 88200NGE User Manual Download Page 463](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938463.webp)
Test Results
Power Blazer
453
Alarms/Errors Overview
S-OAM and MPLS-TP OAM
Alarms
Note:
The following alarms are available when the
CC Function
check box is
Loss Continuity
RX
: No CCM frames with same or lower MEG/MD Level were received
from the peer MEP within an interval equal to 3.5 times the configured
CCM transmission period. The alarm is cleared when at least 3 CCM
frames with same or lower MEG/MD Level from the peer MEP are
received within an interval equal to 3.5 times the configured CCM
transmission period.
Mismerge
RX
: A CCM frame was received from the peer MEP with same MEG/MD
Level but with incorrect MEG ID/MAID value or format. The MAID,
composed of a Domain ID and a Short MA Name strings, is incorrect if
one or both strings are not as expected. The alarm is cleared when no
CCM frames with same MEG/MD Level but with incorrect MEG ID/MAID
value or format are received within an interval equal to 3.5 times the
configured CCM transmission period.
Unexp MEG/MD Lvl
(Unexpected MEG/MD Level)
RX
: A CCM frames was received from the peer MEP with lower
MEG/MD Level. The alarm is cleared when no CCM frames with lower
MEG/MD Level are received within an interval equal to 3.5 times the
configured CCM transmission period.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...