Test Functions
654
88000 Series
OH BERT
The current and history status for enabled overhead group is as follows:
BERT
Overhead group selector: Allows selection of the overhead group on
which Pattern Loss condition and the Bit error statistics will be
reported. Only enabled overhead group from OTUx/ODUx are listed.
Pattern Loss
indicates that the PRBS15 sequence synchronization is
lost.
Bit Error
indicates that bit errors are detected on the selected
overhead group bytes.
Bit Error
Overhead group selector: Allows selection of the overhead group on
which bit error will be injected. Only enabled overhead group from
OTUx/ODUx are listed; All selects all enabled overhead group.
Inject
generates bit errors on the selected overhead group bytes.
Reset
Clears all OTUx/ODUx status as well as
Pattern Loss
and
Bit Error
statistics.
Status
Mode
BERT
SYNC
Green
No alarms/errors.
Overhead group bytes are synchronized.
Red
Alarms/errors condition detected.
Un-synchronized overhead group bytes
condition detected.
Gray
Pending state
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...