![EXFO Power Blazer 88200NGE User Manual Download Page 561](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938561.webp)
Test Results
Power Blazer
551
Summary (EtherSAM)
Summary (EtherSAM)
From the
Test
menu, tap
Results
, and the
Summary
tab.
Note:
For
Dual Test Set
, only Start Time is displayed on the remote module.
Service Configuration/Performance Test Status
indicates the actual
test status as follows:
Start Time
indicates the date and time the test was started. The date
and time is reset every time the test is restarted.
Remote unit in use and locked for Dual Test Set
indicates that this
module is used for
Dual Test Set
as the remote module.
Test Status
Description
“--”
Test has not started.
Disabled
Test/subtests is/are disabled.
Running
Test/subtest is currently running.
Data Transfer
Test/subtest is running but no test traffic is being transmitted.
Completed
, <Verdict> Test/subtest has completed with the test pass/fail verdict. A
fail verdict is declared when a
Link Down
or
LOS
is detected,
or when any SLA parameter fails.
Aborted
,
<
reason
>
Test/subtest has been aborted either manually (Stop) or
automatically from an alarm and the reason why the test has
been aborted is also displayed as follows:
Link down alarm
,
LOS alarm
,
Timeout during execution
,
DTS connection failed
,
Loss of remote connection (DTS)
,
LOPPS-L Alarm
a
,
LOPPS-R Alarm
LOPPS-L / LOPPS-R Alarm
,
Unresolved addresses
,
No test enabled
,
No L2CP Frame Enabled
,
Invalid Burst Configuration
,
CIR disabled for all services
,
Excessive Refill Time
b
,
Stopped
,
NAT detection failed
,
Missing DTS-NAT SW option
a.
Available for
Dual Test Set
in
One-Way Latency
measurement mode.
b.
An excessive refill occurs when the pre-burst and/or post-burst duration last for
more than 2 seconds.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...