Test Setup - Test Configurator, Timer, and System
Power Blazer
283
ODU Channels - Global
The following table indicates the number of tributary slots per
channel:
The table provides a status for each channel using visual indication
as follows:
TX = RX
check box, when selected, allows using the same
tributary slot configuration for both TX and RX.
RX Structure Match
is a live status indicating if the tributary
slot/channel configuration is matching the received signal. Only
configured channels are considered during the validation.
RX
Structure Match
is displayed using different background colors as
follows:
For...
Mapped into...
Tributary slot per channel
ODU3
OPU4
31
ODU2
OPU4
8
ODU1
OPU4
2
ODU0
OPU4
1
Background
Color
Description
White
Tributary slot using background traffic (
B
) or Unallocated (
U
).
Orange
Tributary slot(s) assigned for the selected channel.
Gray
Tributary slot(s) assigned.
Background
Color
Description
Green
Configured structure is matching the received signal.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...