Test Results
Power Blazer
419
Alarms/Errors Overview
GFP (Generic Framing Procedure)
Note:
Available from the GFP-F/GFP-T sub-tab.
Alarms
GFP-LFD
(GFP - Loss of Frame Delineation)
RX
: Indicates that the GFP engine is out of synchronization.
TX
: Generates a sufficient number of cHEC uncorrectable errors to
avoid synchronization.
GFP-EXM
(GFP - Extension Header Mismatch)
RX
: The EXM alarm is declared when the EXI received is different from
the expected EXI (refer to EXI on page 222) without uncorrectable
cHEC, tHEC, eHEC, and no pFCS errors.
GFP-UPM
(GFP - User Payload Mismatch)
RX
: The UPM alarm is declared when the UPI received is different from
the expected Client Data UPI without uncorrectable cHEC, tHEC,
eHEC, and no pFCS errors. The
expected UPI value based on the test structure. Refer to page 818 for
more information on UPI values.
GFP-DCI
(GFP - Defect Clear Indication)
RX
: The DCI alarm is declared when CMF frame is received with an
UPI set to “0000 0011”.
TX
: Generates a client DCI by setting the UPI field to “0000 0011”.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...