Test Setup - Test Configurator, Timer, and System
Power Blazer
235
Interface
Modify Wavelength
button, available with tunable transceivers when
the
TunableOptics
software option is enabled, is used to configure the
transceiver wavelength.
Wavelength
(nm) indicates the actual wavelength value selected.
Use the scroll box and/or the -/+ buttons to select the wavelength.
The minimum and maximum wavelength values are displayed.
Channel Number
indicates the actual ITU channel number based
on ITU Grid.
Frequency
(THz) indicates the actual Frequency based on ITU Grid
Channel Spacing
(GHz) indicates the difference in frequency
between two adjacent channel detected from the transceiver
device.
Restore Previous
restores the current value present in the
transceiver device.
Power Range (dBm
) indicates the transceiver operational RX power
range.
FEC (FlexO BERT)
FEC
check box when selected (default) enables the FEC in TX/RX and
allows detecting, reporting, and correcting up to 15symbol errors
(Correctable) per codeword. If there are over 15 symbol errors
detected, they are reported as uncorrectable errors.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...