Test Setup - Test Configurator, Timer, and System
260
88000 Series
MAC/IP/UDP
The following configuration parameters are available for both
IPv4
and
IPv6
unless otherwise specified.
Quick Ping
button automatically starts the quick Ping utility for the
stream destination IP address and provides either a successful or failed
result. The quick Ping uses 3 attempts, a Delay of 1 second, a Timeout
of 2 seconds, and a Data Size of 32 Bytes. Refer to
Resolve MAC Address
check box, when selected (default), sends a
request to the network to retrieve the MAC address corresponding to
the selected destination IP address. This setting is coupled with the
Resolve MAC Address check box from
MAC address status is displayed. Possible status are:
Source IP Multiplicator
check box, when selected (cleared by
default), allows changing the 7 LSB (Least Significant bit) of the source
IP address as specified in the range:
1-128
(default) or
0-127
. Not
available with eCPRI.
Subnet Mask
(IPv4) allows entering the Subnet Mask for the stream.
The default setting is
255.255.0.0
. Not available when the
Automatic IP
(DHCP)
check box is selected.
Default Gateway
(IPv4) check box, when selected (cleared by
default), allows entering a default Gateway IP address. When the
Default Gateway
check box is selected, its default address is
0.0.0.0
.
The
Default Gateway
address is not configurable when the
Automatic
IP (DHCP)
check box is selected.
Status
Description
--
The
Resolve MAC address
is not enabled.
Resolving
The MAC address is being resolved.
Resolved
The MAC address is resolved.
Failed
The MAC address cannot be resolved.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...