Test Results
Power Blazer
411
Alarms/Errors Overview
Exc. Skew
(Excessive Skew)
RX
: The skew exceeds the defined threshold (see
Errors
Block
is available with Ethernet test applications and 100 GbE over
OTU4. Injection is not available when RS-FEC is enabled.
RX
: Invalid 64b/66b block code are received. An invalid 64b/66b block
is declared when the synchronization field has a value of 00 or 11.
Inv. Marker
(Invalid Marker): Injection is not available when RS-FEC is
enabled.
RX
: There are errors in the 66-bit block alignment marker.
PCS BIP-8
RX
: There are PCS lane bit-interleave parity error. A routine even-parity
check is performed over all bits of a PCS lane, from and including the
previous alignment marker, but not including the current alignment
marker.
PCS BIP-8 Mask
is available with 40GbE over OTU3 test.
RX
: At the OTN ingress, the calculated 8-bit error mask contains at least
one bit set to “1”.
OTN BIP-8
is available with 40GbE over OTU3 test
RX
: Indicates for each lane that at the OTN egress, the calculated 8-bit
error contains at least one bit set to “1”.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...