![EXFO Power Blazer 88200NGE User Manual Download Page 516](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938516.webp)
Test Results
506
88000 Series
Performance Monitoring
For M.2100 ISM: Gives the count of the seconds within which
anomalies (frame bit errors, CRC block errors, etc.) are
Y or at least
one defect occurred. Y depends on the type of DSn/PDH signal as
described in the following table.
BBE
(Background Block Error) (G.828 and G.829 Line): Gives the count
of Errored Blocks not occurring as part of an SES.
Signal
SES Threshold
DS1 (SF)
8 frame bit errors (Near-End)
DS1 (ESF)
320 CRC-6 block errors (Near-End) 320 CRC-6 block errors (Far-End, if FDL
enabled)
E1 (Framed without CRC-4) 28 frame bit errors (Near-End)
E1 (Framed with CRC-4)
805 CRC-4 block errors (Near-End) 805 E-bit errors (Far-End)
DS3 (M13)
2444 P-bit errors (Near-End) or 5 F-bit errors (Near-End)
DS3 (C-bit Parity)
2444 P-bit errors (Near-End) or 5 F-bit errors (Near-End) 2444 FEBE errors
(Far-End)
E2 (Framed)
41 frame bit errors (Near-End)
E3 (Framed)
52 frame bit errors (Near-End)
E4 (Framed)
69 frame bit errors (Near-End)
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...