Test Results
406
88000 Series
Alarms/Errors Overview
Client Frequency
(available with EoOTN 1GbE client)
RX
: The received client signal rate doesn’t meet the standard rate
specification of 1250000000 ± 150000 bps (± 120 ppm).
Errors
Symbol
1
RX/TX
: Invalid code-group is detected/generated in the code.
RX
: An error is detected between the end of a frame and the beginning
of the next frame.
False Carrier
RX
: Data is being received with invalid start of frame.
Block
(available with Ethernet 10G LAN/WAN interface)
RX
: Error block received in frames.
Alignment
(available with 10/100 Mbit/s interface)
RX
: Frames without an integral number of octets in length are
received.
FCS
(Frame Check Sequence)
RX
: Frames with an invalid FCS are received.
Jabber
RX
: Frames larger than 1518 bytes
2
with an invalid FCS are received;
1534 bytes
3
for EoE; 1536 bytes
4
for PBB-TE.
1. Available with Ethernet 100/1000 Mbit/s interface, and EoOTN 1GbE client.
2. Add 4 bytes to this value for each VLAN layer enabled.
3. Add 4 bytes to this value for each VLAN layer enabled in the encapsulated Ethernet payload and 4 bytes for EoE
VLAN when enabled.
4. Add 4 bytes to this value for each VLAN layer enabled in the encapsulated Ethernet payload and 4 bytes for B-VLAN
when enabled.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...