![EXFO Power Blazer 88200NGE User Manual Download Page 330](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938330.webp)
Test Setup - Test Configurator, Timer, and System
320
88000 Series
Services - Profile
Services - Profile
The EtherSAM test application supports the configuration of up to 10
different services individually. All parameters are configurable per service.
From the
Test
menu, tap
Setup
,
Test Configurator
, tap on the services
block, and on the
Profile
tab.
Service Selection and Activation
Select the service to be configured by either using the left/right arrow or by
tapping over the service numbers area then tapping on a specific service
number. An orange background indicates the selected service while a
green background indicates the services that are enabled.
Service
associates a name to the selected service number. Up to 16
characters are allowed. Default service names are
Service 1
to
Service 10
.
Enable
check box when selected (cleared by default) enables the
selected service. However, the service will be generated only when the
test is started. For
Dual Test Set
, services can only be enabled once the
connection with the remote unit is established.
When the
Service Performance Test
is enabled, up to 10 services can
be enabled one after the other, as long as the
Total TX Rate
(bandwidth) is not reached (
Committed
). For example, if the first
service is using the full bandwidth available, then no other service can
be enabled. If the first enabled service uses half bandwidth, then at
least another service can be enabled using up to half bandwidth. Thus,
to enable a second service, first set the CIR value within the non-used
bandwidth (
Available
), then enable it.
When the
Service Performance Test
is disabled, up to 10 services can
be enabled one after the other; the total TX rate is not limited.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...