![EXFO Power Blazer 88200NGE User Manual Download Page 456](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938456.webp)
Test Results
446
88000 Series
Alarms/Errors Overview
OTUCn
Note:
Available with FlexO BERT.
Alarms
AIS
(Alarm Indication Signal)
RX
: The STAT bits in the SM overhead field (byte 3, bits 6 to 8) of the
OTUC #1 are “111” for at least 15 consecutive frames.
TX
: Generates all ones over each OTUC of the signal excluding the OH
framing (FAS and MFAS).
IAE
(Incoming Alignment Error)
RX
: The STAT bits in the SM overhead field (byte 3, bits 6 to 8) of the
OTUC #1 are “010” for at least 15 consecutive frames.
TX
: Generates “010” for the STAT bits in the SM overhead field (byte 3,
bit 6 to 8) of the OTUC #1 continuously.
BDI
(Backward Defect Indication)
RX
: The BDI bit in the SM overhead field (byte 3, bit 5) of the OTUC #1
is “1” for at least 15 consecutive frames.
TX
: Generates “1” for the BDI bit in the SM overhead field (byte 3, bit 5)
of the OTC #1 continuously.
BIAE
(Backward Incoming Alignment Error)
RX
: The BEI/BIAE bits in the SM overhead field (byte 3, bits 1 to 4) are
“1011” for at least 3 consecutive frames.
TX
: Generates “1011” for the BEI/BIAE bits in the SM overhead field
(byte 3, bits 1 to 4) of OTUC continuously.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...