Test Functions
650
88000 Series
FlexE Advanced
Reset/Manual Skew
Allows the selection of a relative delay in nanoseconds that will be
introduced for each PHY.
Reset Skew
sets all TX skew (ns) values to 0.
Manual Skew
allows setting the skew value for each PHY manually.
PHY TX Skew
PHY/Port
indicates the PHY/Port numbers and
All
which
represents the value for all PHY/Port when the
All PHY
check box
is selected.
Skew (ns)
allows setting the skew value for each PHY. Enter
directly the skew value in the field or use the “+” and “-” buttons to
respectively increment or decrement the skew value using the
defined
Skew Inc/Dec Size
value. Tapping and holding the “+” or
“-” button allows reaching the desired value faster using the
defined
Skew Inc/Dec Size
value. Range is from
0
to
1000
ns.
All PHY
, when selected, applies the change(s) to all PHYs at once.
Skew Inc/Dec Size (ns)
allows setting the increment/decrement
value that will be used when changing the Skew (ns) values using
the “+” and “-” buttons. Range is from
0
to
1000
ns.
PHY Skew Alarm Threshold (ns)
Allows setting the threshold value that will be used to declare a skew
alarm:
50
ns to
1000
ns, default is
300
ns (see
Excessive PHY Skew
on
page 449).
Default
button restores the default PHY skew alarm threshold value.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...